Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 260

Details

Autor(en) / Beteiligte
Titel
Assessments of the performance of neutral beam injection on the spherical tokamak EXL-50
Ist Teil von
  • Fusion engineering and design, 2022-07, Vol.180, p.113189, Article 113189
Ort / Verlag
Amsterdam: Elsevier B.V
Erscheinungsjahr
2022
Link zum Volltext
Quelle
Elsevier ScienceDirect Journals Complete
Beschreibungen/Notizen
  • •The low beam energies (20, 30 keV) should be employed on EXL-50 to avoid the excessive shine-through loss.•For the typical EXL-50 plasma parameters, the absorbed power is mainly heating ions.•The orbit loss can be reduced to a negligible magnitude when the plasma current is larger than 200 kA.•For the purpose of heating plasma on EXL-50, the co-current injection should be adapted to obtain the larger power absorption rate. The numerical simulation of the neutral beam injection (NBI) heating in the spherical tokamak EXL-50 has been performed in order to offer a guideline for the practicable engineering design. A series of parameter scans on injected beam energy, plasma density, electron temperature, plasma current and injection direction have been performed with the NBI heating analysis code NUBEAM. The simulation results show that the injected beam energy should be matched with the plasma density to avoid the excessive shine-through loss. For the scenario with central plasma density of 3.0 × 1019 m−3, the 20 keV beam injection has a power absorption rate about 77%, while for the 50 keV beam injection, only 57% injected power has been absorbed by plasma. When the central plasma density increases to 5.0 × 1019 m−3, a power absorption rate more than 70% can be obtained even for the 50 keV beam injection. As the increase in the electron temperature, the injected power is more likely to heat ions while the total absorbed power by plasma roughly remains stable. The increased plasma current leads to the stronger poloidal magnetic field. A qualitative elucidation on the fast ion trajectory has been given to reveal that the orbit loss has been remarkably suppressed by the enhanced poloidal magnetic field. In addition, a comparison of power absorption rate in the co-current and counter-current injection cases has been carried out, which suggests that counter-current injection leads to more orbit loss and hence less power absorption rate.
Sprache
Englisch
Identifikatoren
ISSN: 0920-3796
eISSN: 1873-7196
DOI: 10.1016/j.fusengdes.2022.113189
Titel-ID: cdi_proquest_journals_2692290092

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX