Cooling energy savings and occupant feedback in a two year retrofit evaluation of 99 automated ceiling fans staged with air conditioning
Ist Teil von
  • Energy and buildings, 2021-11, Vol.251, p.111319, Article 111319
Ort / Verlag
Lausanne: Elsevier B.V
Erscheinungsjahr
2021
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • [Display omitted] •Largest known field study of ceiling fans sequenced with air conditioning for cooling.•Mean zone indoor temperature increased 1.9 °C in period after fan installation.•36% total measured cooling season compressor energy savings (from 2.8 to 1.8 W/m2).•Mean ceiling fan power only 8 W, at speeds <60% maximum, fans ran 76% occupied hours.•All interviewees felt fans provided adequate cooling; most preferred automated fans. Controlled air movement is an effective strategy for maintaining occupant comfort while reducing energy consumption, since comfort at moderately warmer temperatures requires less space cooling. Modern ceiling fans provide a 2–4 °C cooling effect at power consumption comparable to LED lightbulbs (2–30 W) with gentle air speeds (0.5–1 m/s). However, very limited design guidance and performance data are available for using ceiling fans and air conditioning together, especially in commercial buildings. We present results from a 29-month field study of 99 automated ceiling fans and 12 thermostats installed in ten air-conditioned buildings in a hot/dry climate in California. Staging ceiling fans to automatically cool before, and then operate together with air conditioning enabled raising air conditioning cooling temperature setpoints in most zones, with overall positive occupant interview and survey responses. Overall measured cooling season (April– October) compressor energy savings were 36%, normalized by floor area served (41% during summer peak billing hours). Weather-normalized changes in zone energy use varied from 24% increase to 73% decrease across 13 compressors, reflecting variation in occupant schedules and other uncontrolled factors in occupied buildings. Median weather-normalized energy savings per compressor were 21%. Staging ceiling fans and air conditioning provided comfort across a wider temperature range, using less energy, than air conditioning alone.
Sprache
Englisch
Identifikatoren
ISSN: 0378-7788
eISSN: 1872-6178
DOI: 10.1016/j.enbuild.2021.111319
Titel-ID: cdi_proquest_journals_2594713404

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX