Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 18060

Details

Autor(en) / Beteiligte
Titel
Lifetime and diffusion distance of singlet oxygen in air under everyday atmospheric conditions
Ist Teil von
  • Physical chemistry chemical physics : PCCP, 2020-10, Vol.22 (38), p.21664-21671
Ort / Verlag
Cambridge: Royal Society of Chemistry
Erscheinungsjahr
2020
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Singlet oxygen is a toxic chemical but powerful oxidant, exploited in many chemical and biological applications. However, the lifetime of singlet oxygen in air under atmospheric conditions is yet to be known. This has limited safe usage of singlet oxygen in air, despite being a strong antimicrobial agent with the unique property of relaxing to breathable oxygen after serving its purpose. Here, we solve this long-standing problem by combining experimental and theoretical research efforts; we generate singlet oxygen using a photosensitizer at a local source and monitor the time-dependent extent of singlet oxygen reaction with probe molecules at a detector, precisely controlling the detector distance from the source. To explain our experimental results, we employ a theoretical model that fully accounts for singlet oxygen diffusion, radiative and nonradiative relaxations, and the bimolecular reaction with probe molecules at the detector. For all cases investigated, our model, with only two adjustable parameters, provides an excellent quantitative explanation of the experiment. From this analysis, we extract the lifetime of singlet oxygen in the air to be 2.80 s at 23 °C under 1 atm, during which time singlet oxygen diffuses about 0.992 cm. The correctness of this estimation is confirmed by a simple mean-first-passage time analysis of the maximum distance singlet oxygen can reach from the source. We also confirm the sterilization effects of singlet oxygen for distances up to 0.6-0.8 cm, depending on the bacteria strain in question, between the bacteria and the singlet oxygen source. The lifetime and diffusion distance of singlet oxygen in air at 23 °C under 1 atm are 2.80 seconds and 0.992 cm, far longer than previously reported.
Sprache
Englisch
Identifikatoren
ISSN: 1463-9076
eISSN: 1463-9084
DOI: 10.1039/d0cp00739k
Titel-ID: cdi_proquest_journals_2448820090

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX