Investigation of the effect of temperature and other significant factors on systematic error and measurement uncertainty in CMM measurements by applying design of experiments
Ist Teil von
  • Measurement : journal of the International Measurement Confederation, 2020-07, Vol.158, p.107692, Article 107692
Ort / Verlag
London: Elsevier Ltd
Erscheinungsjahr
2020
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •Use of Design of Experiments (DoE) with the aim of including the most influential uncertainty factors of CMM measurements.•An investigation into the effect of temperature on systematic error and measurement uncertainty in CMM measurements.•Evaluation of measurement uncertainty based on ISO 15530-3:2011 standard.•Uncertainty budget for different characteristics at different temperatures. The design of experiments was used in this paper in order to determine the significance of particular factors for the parameters that indicate the quality of measurement results obtained by means of a coordinate measuring machine (CMM). Special emphasis was placed on the interaction of temperature and other factors. In accordance with the design of experiments, the diameter and roundness of a ring gauge were measured at the reference temperature and at the temperature of 26 °C. The ISO 15530-3:2011 standard for the assessment of measurement uncertainty of CMM measurements distinguishes systematic error from measurement uncertainty. Thus, separate analyses were done on how temperature, in the first place, but also workpiece position on the CMM table, coordinate system, stylus tip diameter, sampling size and interaction of temperature with other factors affect systematic error and measurement uncertainty. The experimental results showed an increase in systematic error at the higher temperature when the diameter was measured, whereas with roundness, systematic error was even smaller at the higher temperature. As for measurement uncertainty, measurements made at the higher temperature have a significantly greater uncertainty when the diameter is measured, unlike with roundness, where the effect of temperature is almost negligible.
Sprache
Englisch
Identifikatoren
ISSN: 0263-2241
eISSN: 1873-412X
DOI: 10.1016/j.measurement.2020.107692
Titel-ID: cdi_proquest_journals_2441888069

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX