Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
An analytical study on the component-level mechanical functional properties of the thermal structure connecting end frame was conducted, illustrating by advanced composite materials (ACM) C/C and C/SiC. Different grades of component-level experiments and analyses the weakness of composite connecting end frames were carried out, including the screw hole pull-out test, which mainly reflects the features of materials, the bending test of corner beams, and the corner box test with structural characteristics. The failure of different components and the factors have been obtained from this research.