Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 306

Details

Autor(en) / Beteiligte
Titel
Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices
Ist Teil von
  • Hepatology research, 2019-06, Vol.49 (6), p.676-686
Ort / Verlag
Netherlands: Wiley Subscription Services, Inc
Erscheinungsjahr
2019
Link zum Volltext
Quelle
Wiley Online Library - AutoHoldings Journals
Beschreibungen/Notizen
  • Aim Transient elastography (TE) is the gold standard for measurement of liver stiffness. The usefulness of shear wave elastographies (SWE) is well accepted. However, the measurement values cannot be equivalently compared because cut‐off values for the diagnosis of liver fibrosis are different among those devices. We aimed to clarify correlations, to generate the regression equations between TE and SWEs, and to compare the diagnostic ability of each device to diagnose liver fibrosis. Methods A total of 109 patients with chronic liver disease who underwent liver biopsy and same‐day evaluation of liver stiffness using six ultrasound devices were analyzed. The diagnostic ability of liver stiffness from each ultrasound device and correlations between TE and each SWE were analyzed. Results Liver stiffness measured by all six ultrasound devices increased significantly as liver fibrosis stage advanced (P < 0.001). Receiver operating characteristic (ROC) curve analysis for predicting significant fibrosis (≥F2) and cirrhosis yielded area under the ROC curve (AUROC) values based on TE of 0.830 (95% confidence interval [CI], 0.755–0.905) and 0.959 (95% CI, 0.924–0.995), respectively. The AUROCs for predicting significant fibrosis (≥F2) and cirrhosis (F4) based on SWE from all five ultrasound devices were over 0.8 and 0.9, respectively. Furthermore, the correlation coefficients between TE values and SWE values from five ultrasound devices were all over 0.8, indicating a strong relationship. Conclusion Our study showed strong correlations between TE and SWEs with high correlation coefficients. The regression equations between TE and SWEs demonstrated the ability to compare the measurement values in each device equivalently.
Sprache
Englisch
Identifikatoren
ISSN: 1386-6346
eISSN: 1872-034X
DOI: 10.1111/hepr.13319
Titel-ID: cdi_proquest_journals_2246041214

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX