Enhancement of carbon detection sensitivity in laser induced breakdown spectroscopy with low pressure ambient helium gas
Ist Teil von
  • Spectrochimica acta. Part B: Atomic spectroscopy, 2019-01, Vol.151, p.26-32
Ort / Verlag
Oxford: Elsevier B.V
Erscheinungsjahr
2019
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Carbon detection is usually difficult to carry out with high sensitivity and minimally destructive effect. While the conventional laser induced breakdown spectroscopy (LIBS) method operated with atmospheric ambient air is well known as a powerful and versatile analytical tool, it suffers nevertheless from the low sensitivity of C detection when measured in both atmospheric and low pressure ambient air with the more adverse effect found in the former case. This was shown to have its origin in the serious time mismatching effect between the formation of the shock wave plasma by the ablated major host elements and the premature fast passage of the much lighter ablated C atom. However, this study shows the result of high sensitivity C analysis of stone samples using LIBS technique with relatively low laser pulse energy of 60 mJ and low pressure He ambient gas without showing visible surface damage. The helium gas provides the additional delayed excitation by the He metastable excited states through the Penning-like ionization process. The C emission intensities measured from the jasper and black stone in 2.6 kPa He ambient gas are in general significantly higher than those measured in 0.5 kPa ambient air. The enhancement is shown to increase reaching an 8 fold enhancement with increased laser energy up to 60 mJ before undesirable surface damage is created. A further measurement of C emission using pelletized KBr mixtures with various CaCO3 concentrations reveals a straight calibration line of rather large slope with extrapolated zero intercept and estimated detection limit of around 0.6 ppm, demonstrating its potential application for highly sensitive quantitative analysis of C with minimal destructive effect. [Display omitted] •Detection of C in precious stones using low pressure He LIBS.•An about 8 fold intensity increase is exhibited for C emission line.•Linear calibration line with high slope and zero intercept for C line.•Detection limit of 0.6 ppm for C I 247.8 nm.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX