Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 45118

Details

Autor(en) / Beteiligte
Titel
Experimental study on the effect of coupling parabolic trough collector with double slope solar still on its performance
Ist Teil von
  • Solar energy, 2018-03, Vol.163, p.54-61
Ort / Verlag
New York: Elsevier Ltd
Erscheinungsjahr
2018
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •The performance of solar still coupled with parabolic trough collector (PTC) was experimentally studied.•Freshwater productivity for solar still with PTC is higher than that for conventional solar still.•Daily productivity of conventional solar still and solar still with tracked PTC is 10.93 and 4.51 kg/m2 in summer.•The efficiency of solar still in summer is greater than winter and the efficiency of conventional solar still is the largest.•Cost of one liter of yield freshwater for solar still with tracked PTC is the lowest (0.0234 $/L). The performance of coupling parabolic trough collector (PTC) with double slope solar still is investigated experimentally. The incident solar energy on the PTC is transferred to the solar still by oil pipes connected with finned-piped loop heat exchanger imbedded in the solar still. The experiments are conducted at summer and winter times for three systems; conventional solar still, solar still with fixed PTC and with tracked PTC and for two cases of saline water depth in the basin 20 and 30 mm. The results illustrate that the solar still with PTC has higher sill temperature and productivity compared with conventional solar still. The freshwater productivity of solar still with tracked PTC is higher than that of fixed PTC by about 28.1% and for conventional solar still by about 142.3% at saline water depth 20 mm in summer. Freshwater productivity is about 8.53 kg/m2/ day and 4.03 kg/m2/day for solar still coupled with fixed PTC in the summer and winter respectively. The results also illustrate that the performance of solar still in winter is smaller than summer for all studied cases and systems. In summer and at saline water depth 20 mm, the daily efficiency of the conventional solar still, solar still with fixed PTC and solar still with tracked PTC are 36.87, 23.26 and 29.81% respectively.
Sprache
Englisch
Identifikatoren
ISSN: 0038-092X
eISSN: 1471-1257
DOI: 10.1016/j.solener.2018.01.043
Titel-ID: cdi_proquest_journals_2103109910

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX