Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 42
Heart (British Cardiac Society), 2016-05, Vol.102 (Suppl 3), p.A14-A15
2016
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
20 Do atriopulmonary (AP) fontan dimensions using CMR influence the development of atrial tachyarrhythmia?
Ist Teil von
  • Heart (British Cardiac Society), 2016-05, Vol.102 (Suppl 3), p.A14-A15
Ort / Verlag
London: BMJ Publishing Group LTD
Erscheinungsjahr
2016
Quelle
BMJ Journals Archiv - DFG Nationallizenzen
Beschreibungen/Notizen
  • IntroductionAtrial tachyarrhythmia is regarded as a late consequence of the Fontan circulation, particularly in those with an AP Fontan and is associated with significant morbidity and mortality. Developing methods to recognise those at the highest risk will allow early intervention, improving patient outcomes.PurposeTo establish relationship between AP Fontan chamber (FC) dimensions, ventricular volumes and function and the development of atrial arrhythmia (AR).MethodsModified AP Fontan patients with CMR (1.5T, Avanto, Siemens) were reviewed (Figure 1). Horizontal long axis (HLA, TrueFISP cine, flip angle 80, TR/TE 50/1.26ms, retrospective ECG gating) and transaxial 3D MRA non-contrast (Modified Siemens Whole Heart coronary artery sequence, respiratory navigator, ECG-triggered, free breathing, slice thickness 2.00mm) of the FC and the left atrium were examined.Abstract 20 Figure 1HLA of 48 year old male with 5 ablations. End-diastolic area of 69cm2. Slow flow can be seen in the FCResults55 patients 58% female and 42% male, mean age 33yrs (SD 7.9). 32 patients suffered a documented AR, most commonly atrial flutter (79%). There was a significant difference in age between the two groups with those having an AR tending to be older (36yrs vs 29yrs p < 0.05) the age of procedure was also younger in the AR group (6yrs vs. 10yrs p < 0.05)  (Table 1). There was no difference in ventricular ejection fraction (p > 0.05). There were no significant differences in atrial parameters between the two groups (p > 0.05), however all measures of the FC were statistically different with larger measures occurring in the AR group (p < 0.05). Receiver operator characteristic curves were constructed for each of the atrium and FC variables. Only end diastolic area and FC longitudinal dimension produced statistically significant results (ROC 0.745 P < 0.05 and 0.719 p < 0.05). Using an upper limit of 27cm2 for end diastolic FC area odds ratio of AR was 8.57 (p < 0.05) with a sensitivity of 0.596 and a specificity of 0.870.Abstract 20 Table 1Patient demographics and CMR parameters Non-arrhythmia group N=23 (Standard deviation) Arrhythmia Group N=32 (Standard Deviation) Age (yrs) 29(5)36(9)P < 0.05 * Age of Fontan Procedure (yrs) 6(4)1 (9)P < 0.05 * Ejection fraction (%) 55(11)55(12)P > 0.05 * End Diastolic Area of Fontan chamber (cm 2 ) 19(8)30(16)P < 0.05 * End Diastolic Longitudinal Value of Fontan Chamber (cm 2 ) 4(1)6(2)P < 0.05 * End Systolic Area of Fontan Chamber (cm 2 ) 23(11)32(16)P < 0.05 * End Systolic longitudinal Value Fontan Chamber (cm 2 ) 5(1)6(2)P < 0.05 * *P values represent significance level of between group t-testsConclusionsIncreasing AP FC size is associated with increased risk of AR.
Sprache
Englisch
Identifikatoren
ISSN: 1355-6037
eISSN: 1468-201X
DOI: 10.1136/heartjnl-2016-309668.20
Titel-ID: cdi_proquest_journals_1786541858
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX