Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 2 von 59

Details

Autor(en) / Beteiligte
Titel
Diagnostic Classification of the Instantaneous Wave-Free Ratio Is Equivalent to Fractional Flow Reserve and Is Not Improved With Adenosine Administration
Ist Teil von
  • Journal of the American College of Cardiology, 2013-04, Vol.61 (13), p.1409-1420
Ort / Verlag
New York: Elsevier Inc
Erscheinungsjahr
2013
Quelle
EZB-FREE-00999 freely available EZB journals
Beschreibungen/Notizen
  • Objectives This study sought to determine if adenosine administration is required for the pressure-only assessment of coronary stenoses. Background The instantaneous wave-free ratio (iFR) is a vasodilator-free pressure-only measure of the hemodynamic severity of a coronary stenosis comparable to fractional flow reserve (FFR) in diagnostic categorization. In this study, we used hyperemic stenosis resistance (HSR), a combined pressure-and-flow index, as an arbiter to determine when iFR and FFR disagree which index is most representative of the hemodynamic significance of the stenosis. We then test whether administering adenosine significantly improves diagnostic performance of iFR. Methods In 51 vessels, intracoronary pressure and flow velocity was measured distal to the stenosis at rest and during adenosine-mediated hyperemia. The iFR (at rest and during adenosine administration [iFRa]), FFR, HSR, baseline, and hyperemic microvascular resistance were calculated using automated algorithms. Results When iFR and FFR disagreed (4 cases, or 7.7% of the study population), HSR agreed with iFR in 50% of cases and with FFR in 50% of cases. Differences in magnitude of microvascular resistance did not influence diagnostic categorization; iFR, iFRa, and FFR had equally good diagnostic agreement with HSR (receiver-operating characteristic area under the curve 0.93 iFR vs. 0.94 iFRa and 0.96 FFR, p = 0.48). Conclusions iFR and FFR had equivalent agreement with classification of coronary stenosis severity by HSR. Further reduction in resistance by the administration of adenosine did not improve diagnostic categorization, indicating that iFR can be used as an adenosine-free alternative to FFR. (Classification Accuracy of Pressure-Only Ratios Against Indices Using Flow Study [CLARIFY]; NCT01118481 )
Sprache
Englisch
Identifikatoren
ISSN: 0735-1097
eISSN: 1558-3597
DOI: 10.1016/j.jacc.2013.01.034
Titel-ID: cdi_proquest_journals_1645201472

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX