Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 415

Details

Autor(en) / Beteiligte
Titel
Damage and failure of underground subway stations under different soil constraint conditions
Ist Teil von
  • PloS one, 2023-04, Vol.18 (4), p.e0284074-e0284074
Ort / Verlag
United States: Public Library of Science
Erscheinungsjahr
2023
Quelle
Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
Beschreibungen/Notizen
  • Investigations from past earthquakes have shown that underground subway stations can suffer excessive deformation under strong seismic loads, leading to the damage of critical components and the collapse of structures. This study presents the results of finite element analyses on the seismic damage of underground subway stations installed under different soil constraint conditions. The plastic hinge distribution and damage characteristics of cut and cover double-storey and three-storey subway stations are analyzed using the finite element method software ABAQUS. Combined with the static analysis results of the column sections, a discriminant method for bending plastic hinges is presented. The numerical results show that the collapse of the subway stations begins with the failure of the bottom columns' bottom sections, which leads to the bending of the plates and the destruction of the whole structure. The bending deformation at the end section of columns has an approximatively linear relationship with the inter-storey drift ratio, and the change in soil conditions shows no apparent influence. The sidewall deformation behavior varies significantly under different soil conditions, and the bending deformation at the bottom section of sidewalls increases along with an increase in the soil-structure stiffness ratio at the same inter-storey drift deformation level. The sidewall bending ductility ratio of the double-storey and three-storey stations at the elastic-plastic drift ratio limit increases by 61.6% and 26.7%, respectively. In addition, the fitting curves between the component bending ductility ratio and inter-storey drift ratio based on the analysis results are also presented. The findings may provide a helpful reference for the seismic performance evaluation and design of underground subway stations.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX