Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 108
IEEE transactions on biomedical engineering, 1997-08, Vol.44 (8), p.706-719
1997
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
The effects of inhomogeneities and anisotropies on electrocardiographic fields: a 3-D finite-element study
Ist Teil von
  • IEEE transactions on biomedical engineering, 1997-08, Vol.44 (8), p.706-719
Ort / Verlag
New York, NY: IEEE
Erscheinungsjahr
1997
Quelle
IEEE Xplore
Beschreibungen/Notizen
  • The aim of this study was to quantify the effects of selected inhomogeneities and anisotropies on computed electric potential fields associated with the electrocardiographic forward problem. The model construction was based on the Utah Torso model and included geometry for major anatomical structures such as subcutaneous fat, skeletal muscle, and lungs, as well as for epicardial fatpads, major arteries and veins, and the sternum, ribs, spine, and clavicles. Measured epicardial potentials served as the electrical source for solutions to the electrocardiographic forward problem computed using the finite element method (FEM). The geometry of the torso model for each simulation was constant, but different combinations of conductivities were assigned to individual organs or tissues. Comparisons of different conductivity combinations followed one of two basic schemes: 1) a homogeneous torso served as the reference against which we compared simulations with a single organ or tissue and assigned its nominal conductivity, or 2) a fully inhomogeneous torso served as the reference and we removed the effect of individual organs or tissues by assigning it the homogeneous conductivity value. When single inhomogeneities were added to an otherwise homogeneous isotropic model, anisotropic skeletal muscle (at a 15:1 anisotropy ratio) and the right and left lung had larger average effects (12.8, 12.7, and 12.1% relative error (RE), respectively) than the other inhomogeneities tested. Our results for removing single inhomogeneities show that the subcutaneous fat, the anisotropic skeletal muscle (with the degree of anisotropy equal to 7:1), and the lungs have larger average impacts on the body surface potential distributions than other elements of the model (with values of 14.9, 12.6, and 11.7% RE, respectively). The results also show that the size of the effect depended strongly on the distribution of epicardial potentials. The results of this study suggest that accurate representation of tissue inhomogeneity has a significant effect on the accuracy of the forward solution, with regions near the torso surface playing a larger role, in general, than those near the heart.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX