Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 698

Details

Autor(en) / Beteiligte
Titel
The value of 3.0 Tesla diffusion-weighted MRI for pelvic nodal staging in patients with early stage cervical cancer
Ist Teil von
  • European journal of cancer (1990), 2012-12, Vol.48 (18), p.3414-3421
Ort / Verlag
Kidlington: Elsevier
Erscheinungsjahr
2012
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • Abstract Objective The purpose of this study is to investigate the diagnostic accuracy of 3.0 Tesla (3T) diffusion-weighted magnetic resonance imaging (MRI) in addition to conventional MRI for the detection of lymphadenopathy in patients with early stage cervical cancer compared to histopathological evaluation of the systematically removed pelvic lymph nodes as reference standard. Methods 68 fédération internationale de gynécologie obstétrique (FIGO) stage Ia2 to IIb cervical cancer patients were included. Sensitivity and specificity rates for two experienced observers were computed for the detection of lymphatic metastasis. Reproducibility of conventional MRI was tested by kappa statistics. The variables included in the analysis were: size of the long axis, short axis, ratio short to long axis and apparent diffusion coefficient (ADC). Results Nine patients had 15 positive pelvic nodes at histopathological examination. The sensitivity and specificity of lymphatic metastasis detection by predefined conventional MRI characteristics was 33% (95% Confidence Interval (CI) 3–64) and 83% (95% CI 74–93) on patient level, and 33% (95% CI 7–60) and 97% (95% CI 95–99) on regional level respectively for observer 1. For observer 2 the sensitivity was 33% (95% CI 3–64) and the specificity 93% (95% CI 87–100) on patient level, and 25% (95% CI 1–50) and 98% (95% CI 97–100) on regional level, respectively. The kappa-value for reproducibility of metastasis detection on regional level was 0.50. The short axis diameter showed the highest diagnostic accuracy (area under the curve (AUC) = 0.81 95% CI 0.70–0.91); ADC did not improve diagnostic accuracy (AUC = 0.83 95% CI 0.73–0.93). Conclusions Diffusion-weighted MRI did not result in additional diagnostic value compared to conventional MRI.
Sprache
Englisch
Identifikatoren
ISSN: 0959-8049
eISSN: 1879-0852
DOI: 10.1016/j.ejca.2012.06.022
Titel-ID: cdi_pascalfrancis_primary_26691778

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX