Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 13 von 248

Details

Autor(en) / Beteiligte
Titel
Electric current paths in a Si:P delta-doped device imaged by nitrogen-vacancy diamond magnetic microscopy
Ist Teil von
  • Nanotechnology, 2023-01, Vol.34 (1), p.15001
Ort / Verlag
United States: IOP Publishing
Erscheinungsjahr
2023
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Abstract The recently-developed ability to control phosphorous-doping of silicon at an atomic level using scanning tunneling microscopy, a technique known as atomic precision advanced manufacturing (APAM), has allowed us to tailor electronic devices with atomic precision, and thus has emerged as a way to explore new possibilities in Si electronics. In these applications, critical questions include where current flow is actually occurring in or near APAM structures as well as whether leakage currents are present. In general, detection and mapping of current flow in APAM structures are valuable diagnostic tools to obtain reliable devices in digital-enhanced applications. In this paper, we used nitrogen-vacancy (NV) centers in diamond for wide-field magnetic imaging (with a few-mm field of view and micron-scale resolution) of magnetic fields from surface currents flowing in an APAM test device made of a P delta-doped layer on a Si substrate, a standard APAM witness material. We integrated a diamond having a surface NV ensemble with the device (patterned in two parallel mm-sized ribbons), then mapped the magnetic field from the DC current injected in the APAM device in a home-built NV wide-field microscope. The 2D magnetic field maps were used to reconstruct the surface current densities, allowing us to obtain information on current paths, device failures such as choke points where current flow is impeded, and current leakages outside the APAM-defined P-doped regions. Analysis on the current density reconstructed map showed a projected sensitivity of ∼0.03 A m −1 , corresponding to a smallest-detectable current in the 200 μ m wide APAM ribbon of ∼6 μ A. These results demonstrate the failure analysis capability of NV wide-field magnetometry for APAM materials, opening the possibility to investigate other cutting-edge microelectronic devices.
Sprache
Englisch
Identifikatoren
ISSN: 0957-4484
eISSN: 1361-6528
DOI: 10.1088/1361-6528/ac95a0
Titel-ID: cdi_osti_scitechconnect_1894607

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX