Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 15 von 1170

Details

Autor(en) / Beteiligte
Titel
Degradation Mechanisms of Magnesium Metal Anodes in Electrolytes Based on (CF3SO2)2N– at High Current Densities
Ist Teil von
  • Langmuir, 2017-09, Vol.33 (37), p.9398-9406
Ort / Verlag
United States: American Chemical Society
Erscheinungsjahr
2017
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • The energy density of rechargeable batteries utilizing metals as anodes surpasses that of Li ion batteries, which employ carbon instead. Among possible metals, magnesium represents a potential alternative to the conventional choice, lithium, in terms of storage density, safety, stability, and cost. However, a major obstacle for metal-based batteries is the identification of electrolytes that show reversible deposition/dissolution of the metal anode and support reversible intercalation of ions into a cathode. Traditional Grignard-based Mg electrolytes are excellent with respect to the reversible deposition of Mg, but their limited anodic stability and compatibility with oxide cathodes hinder their applicability in Mg batteries with higher voltage. Non-Grignard electrolytes, which consist of ethereal solutions of magnesium­(II) bis­(trifluoromethanesulfonyl)­imide (Mg­(TFSI)2), remain fairly stable near the potential of Mg deposition. The slight reactivity of these electrolytes toward Mg metal can be remedied by the addition of surface-protecting agents, such as MgCl2. Hence, ethereal solutions of Mg­(TFSI)2 salt with MgCl2 as an additive have been suggested as a representative non-Grignard Mg electrolyte. In this work, the degradation mechanisms of a Mg metal anode in the TFSI-based electrolyte were studied using a current density of 1 mA cm–2 and an areal capacity of ∼0.4 mAh cm–2, which is close to those used in practical applications. The degradation mechanisms identified include the corrosion of Mg metal, which causes the loss of electronic pathways and mechanical integrity, the nonuniform deposition of Mg, and the decomposition of TFSI– anions. This study not only represents an assessment of the behavior of Mg metal anodes at practical current density and areal capacity but also details the outcomes of interfacial passivation, which was detected by simple cyclic voltammetry experiments. This study also points out the absolute absence of any passivation at the electrode–electrolyte interface for the premise of developing electrolytes compatible with a metal anode.
Sprache
Englisch
Identifikatoren
ISSN: 0743-7463
eISSN: 1520-5827
DOI: 10.1021/acs.langmuir.7b01051
Titel-ID: cdi_osti_scitechconnect_1418163
Format
Schlagworte
ENERGY STORAGE, metal anode

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX