Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 355

Details

Autor(en) / Beteiligte
Titel
Early and Mid-Term Outcomes of Transcatheter Aortic Valve Replacement Using the New Generation Self-Expanding Corevalve Evolut R Device
Ist Teil von
  • Structural heart (Online), 2018-05, Vol.2 (3), p.229-234
Ort / Verlag
Taylor & Francis
Erscheinungsjahr
2018
Link zum Volltext
Quelle
Taylor & Francis Journals Auto-Holdings Collection
Beschreibungen/Notizen
  • Background: To assess early and mid-term efficacy of transcatheter aortic valve replacement (TAVR) using the new-generation CoreValve Evolut R (Medtronic Inc., Galway, Ireland). Methods: This is a prospective, single-center study. All consecutive patients undergoing TAVR with 23-, 26-, 29-, 34-mm Evolut R valve were included. In a secondary analysis, patients undergoing Evolut R implantation were compared using the propensity score method with a historical cohort of patients who underwent CoreValve implantation in our institution. Results: From March 2015 to September 2017, a total of 320 patients with a median age of 81.1 years (IQR 77-84) and mean STS score of 4.9 ± 3.1% were treated. Device success was obtained in 300 patients (93.8%). Effective recapture and repositioning of the valve due to initial suboptimal deployment was accomplished in 40 patients (12.5%). Post-TAVR transthoracic echocardiogram showed a reduction in mean gradient from 49.1 ± 18.2 mmHg to 7.6 ± 0.4 mmHg (p < 0.001). Moderate paravalvular regurgitation (PVR) was observed in 4.2% patients. No patient had severe PVR. At 30-day, all-cause and cardiovascular mortality rates were 2.2% and 1.9%, respectively; disabling stroke occurred in 5 patients (1.6%). Life-threatening and major bleeding occurred in 16 (5.0%) and 42 (13.1%) patients, respectively. Pacemaker implantation rate was 12.6%. Compared with the CoreValve, Evolut R use was associated with higher device success (92.8% vs. 79.7%, p < 0.001) and lower rates of moderate or severe PVR (2.1% vs. 14.4%, p < 0.001), minor vascular complications (4.9% vs. 14.5%, p < 0.001), and pacemaker implantation (13.5% vs. 21.0%, p = 0.026). Conclusion: In this prospective, single-center study, TAVR using the new-generation self-expanding Evolut R system, was associated with high device success rate, excellent hemodynamics, and low early complications rates.
Sprache
Englisch
Identifikatoren
ISSN: 2474-8706
eISSN: 2474-8714
DOI: 10.1080/24748706.2018.1440097
Titel-ID: cdi_informaworld_taylorfrancis_310_1080_24748706_2018_1440097

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX