Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
A strategy to replace the damaged element for fault-tolerant induction motor drive
Ist Teil von
2008 5th International Conference on Electrical Engineering, Computing Science and Automatic Control, 2008, p.51-55
Ort / Verlag
IEEE
Erscheinungsjahr
2008
Quelle
IEEE Electronic Library Online
Beschreibungen/Notizen
In this paper, the best moment to replace to the damaged element in a fault-tolerant induction motor drive working with a open-loop and closed-loop control is presented, a previous stage of fault-diagnostic to detect a short-circuit or open-circuit failure in the power device is considered. The technique is based on the connection of bidirectional switches to electrically isolate the damaged element by mean of fuse blown corresponding and to replace only the damaged device by another healthful one at the most suitable moment, the main issue is to diminish the tracking error of the motor current during the fault transient. Experimental and simulation results are obtained in order to validate the technique proposed.