Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Two-parameter Identification Method of Deadtime Effect Voltage Error Model during Self-commission
Ist Teil von
IEEE transactions on power electronics, 2023-12, Vol.38 (12), p.1-16
Ort / Verlag
New York: IEEE
Erscheinungsjahr
2023
Quelle
IEEE Xplore
Beschreibungen/Notizen
An identification method is presented for the arctan two-parameter model, which describes the deadtime effect voltage error of PMSM drives' three-phase voltage source inverter (VSI) during self-commission. In this method, the motor maintains a standstill during the whole identification process. First, a disturbance observer is used to improve the tracking performance of the total voltage error. Then, a technique is used to extract the deadtime effect voltage error from the total voltage error without a voltage sensor during the standstill condition. Finally, the core algorithm (utilizing the bisection method) is developed to solve the coupling problem in the two-parameter identification process, such that the parameters in the model converge simultaneously. Furthermore, a sufficient condition for the convergence of the algorithm is given, and a mathematical proof is presented. Experimental results show that the deadtime effect voltage error estimated by our method is closer to the measured voltage error than other state-of-the-art methods proposed in the literature.