Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 276

Details

Autor(en) / Beteiligte
Titel
Implantable cardioverter-defibrillators in previously undiagnosed patients with catecholaminergic polymorphic ventricular tachycardia resuscitated from sudden cardiac arrest
Ist Teil von
  • European heart journal, 2019-09, Vol.40 (35), p.2953-2961
Ort / Verlag
England: Oxford University Press
Erscheinungsjahr
2019
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Abstract Aims In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), implantable cardioverter-defibrillator (ICD) shocks are sometimes ineffective and may even trigger fatal electrical storms. We assessed the efficacy and complications of ICDs placed in patients with CPVT who presented with a sentinel event of sudden cardiac arrest (SCA) while undiagnosed and therefore untreated. Methods and results We analysed 136 patients who presented with SCA and in whom CPVT was diagnosed subsequently, leading to the initiation of guideline-directed therapy, including β-blockers, flecainide, and/or left cardiac sympathetic denervation. An ICD was implanted in 79 patients (58.1%). The primary outcome of the study was sudden cardiac death (SCD). The secondary outcomes were composite outcomes of SCD, SCA, appropriate ICD shocks, and syncope. After a median follow-up of 4.8 years, SCD had occurred in three patients (3.8%) with an ICD and none of the patients without an ICD (P = 0.1). SCD, SCA, or appropriate ICD shocks occurred in 37 patients (46.8%) with an ICD and 9 patients (15.8%) without an ICD (P < 0.0001). Inappropriate ICD shocks occurred in 19 patients (24.7%) and other device-related complications in 22 patients (28.9%). Conclusion In previously undiagnosed patients with CPVT who presented with SCA, an ICD was not associated with improved survival. Instead, the ICD was associated with both a high rate of appropriate ICD shocks and inappropriate ICD shocks along with other device-related complications. Strict adherence to guideline-directed therapy without an ICD may provide adequate protection in these patients without all the potential disadvantages of an ICD.
Sprache
Englisch
Identifikatoren
ISSN: 0195-668X
eISSN: 1522-9645
DOI: 10.1093/eurheartj/ehz309
Titel-ID: cdi_hal_primary_oai_HAL_hal_04000083v1
Format
Schlagworte
Life Sciences

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX