Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 33
Journal of electromyography and kinesiology, 2003-06, Vol.13 (3), p.273-279
2003
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings
Ist Teil von
  • Journal of electromyography and kinesiology, 2003-06, Vol.13 (3), p.273-279
Ort / Verlag
England: Elsevier Ltd
Erscheinungsjahr
2003
Quelle
MEDLINE
Beschreibungen/Notizen
  • The evolution in impedance at the electrode-skin interface of Beckman and Red Dot electrodes was assessed during long-term recordings. Impedance was measured between each pair of electrodes, arranged in a bipolar configuration on tibialis anterior ( n=13). A waveform constructed of sinusoids of known frequencies, evenly distributed on a log scale from 1–16,384 Hz, was applied through the electrodes, and the result recorded by a DAQ system. SEMG signals were recorded at 1000 Hz during isometric dorsiflexion contractions of 30 s, performed every 15 min for 2 h. Impedance data were acquired at 65,536 Hz immediately before and after SEMG recordings. Large individual differences in impedance levels were observed at low frequencies. At high frequencies, impedance values depended only on the electrode type. Impedance decreased steadily with time for Beckman electrodes ( p < 0.05), but did not decrease significantly for Red Dot electrodes. The magnitude of the reduction over time varied widely between individuals, and was related to the initial impedance values. The impedance-bandwidth product remained constant for each electrode type (95% confidence intervals 146.2–148.2 and 126.1–127.8 for Beckman and Red Dot electrodes respectively). When skin impedance is electrically modelled with a simple network containing a resistor and a capacitor, the capacitance varies with the properties of the electrode used, whereas resistance is dependent on the subject. Furthermore, the EMG spectrum is unaffected by impedance provided skin preparation is sufficient to reduce the impedance below 55 kΩ.
Sprache
Englisch
Identifikatoren
ISSN: 1050-6411
eISSN: 1873-5711
DOI: 10.1016/S1050-6411(02)00097-4
Titel-ID: cdi_hal_primary_oai_HAL_hal_02463254v1

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX