Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 4 von 123

Details

Autor(en) / Beteiligte
Titel
Ultrasensitive sensing of Androctonus australis hector scorpion venom toxins in biological fluids using an electrochemical graphene quantum dots/nanobody-based platform
Ist Teil von
  • Talanta (Oxford), 2018-12, Vol.190, p.182-187
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2018
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Rapid and sensitive detection of low levels of scorpion venom toxins in biological fluids is of tremendous importance for decision-taking in cases of envenomation by scorpions stings. In Tunisia, at least 1200 severe envenomation cases by Androctonus australis hector (Aah) scorpion stings were reported annually. In this work, we report on a novel electrochemical immuno-sandwich to detect the Aah50 toxic fraction within the Aah scorpion venom using the bispecific nanobody format specially designed to highly recognize and neutralize the two most toxic molecules in the AahG50 venom fraction (i.e. AahI and AahII toxins), graphene quantum dots (GQDs) constructed on the surface carbon screen-printed electrodes. Hydroquinone/H2O2/peroxidase system was used to amplify the current in order to achieve the detection of low levels of AahG50. Electrochemical studies revealed a high sensitivity toward the AahG50 with a sensitivity of 18.2 nA mL pg–1 and a picomolar limit of detection as low as 0.55 pg mL–1. The platform exhibits very good metrological performances such as repeatability, reproducibility, selectivity and long storage stability. Matrix effect was found to be insignificant as demonstrated by assays performed in human blood serum and urine. A sensitive electrochemical GQDs/nanobody-based platform for the sensing of AahG50 venom toxins from Androctonus australis hector scorpion stings in biological fluids. [Display omitted] •A sensitive amperometric immunosandwich nanobody sensor was developed.•The toxin detection event was monitored by a hydroquinone-H2O2-peroxidase system.•The LOD was founded to be 0.55 pg.mL−1 with a sensitivity of 18.2 nA.mL.pg−1.•Good metrological performances were demonstrated.•Human blood serum and urine fluids were used as real matrix.
Sprache
Englisch
Identifikatoren
ISSN: 0039-9140
eISSN: 1873-3573
DOI: 10.1016/j.talanta.2018.07.087
Titel-ID: cdi_hal_primary_oai_HAL_hal_01873752v1

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX