Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 53

Details

Autor(en) / Beteiligte
Titel
Determination of residues of sulfonylurea herbicides in soil by using microwave-assisted extraction and high performance liquid chromatographic method/ODREDIVANJE OSTATAKA SULFONILUREA HERBICIDA U ZEMLJISTU PRIMENOM MIKROTALASNE EKSTRAKCIJE I TECNE HROMATOGRAFIJE VISOKIH PERFORMANSI
Ist Teil von
  • Hemijska industrija, 2017-07, Vol.71 (4), p.289
Ort / Verlag
Association of Chemical Engineers of Serbia
Erscheinungsjahr
2017
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • A modified method for the analysis of nicosulfuron, rimsulfuron and prosulfuron was developed and validated by using microwave-assisted extraction (MAE) and ultra-performance liquid chromatography with diode array detection in the ultraviolet region (HPLC-UV-DAD). The most important experimental parameters of extraction procedure and HPLC-UV-DAD technique were optimised in respect to those sulfonylurea herbicides. High recoveries of the microwave-assisted extraction were obtained by using a dichloromethane-acetonitrile mixture (2:1 volume ratio) acidified with acetic acid (0.8 vol.%) with the addition of urea. The mean recoveries at three spiking levels ranged from 97.47 to 98.76% for nicosulfuron, 97.88 to 99.17% for rimsulfuron and from 97.91 to 99.83% for prosulfuron. The limits of detection of nicosulfuron, rimsulfuron and prosulfuron were 0.95, 0.91 and 0.89 [micro]g [kg.sup.-1], respectively. The accuracy of the developed method was confirmed by HPLC coupled with tandem mass spectrometry parallel analyses. The developed method was used to investigate the dissipation dynamics of sulfonylurea herbicides in the real field trials in Vojvodina Province, Serbia. The obtained half-lives were 0.05, 0.23 and 0.15 days for recommended dose application of nicosulfuron, rimsulfuron and prosulfuron, respectively. Low residues and short half-life in soil suggested that the risk to sensitive rotational crops after application of those sulfonylurea herbicides is low when they are used in the appropriate dosages. Keywords: sulfonylurea herbicide, microwave-assisted extraction, HPLC-UV-DAD, soil, dissipation. IZVOD (Naucni rad) Modifikovana metoda za analizu nikosulfurona, rimsulfurona i prosulfurona razvijena je i validovana uz pomoc mikrotalasne ekstrakcije (MAE) i tecne hromatografije visokih performansi sa ultravioletnim detektorom sa nizom dioda (HPLC-UV-DAD). Najvazniji eksperimentalni parametri ekstrakcione procedure i HPLC-UV-DAD tehnike su optimizirani za ispitivane sulfonilurea herbicide. Visoki prinosi mikrotalasne ekstrakcije dobijeni su primenom mesavine dihlormetan-acetonitril (zapreminski odnos 2:1) zakiseljene sa sircetnom kiselinom (0,8 zapr.%) uz dodatak uree. Prosecan prinos na tri spajkovana nivoa se kretao u opsegu od 97,47 do 98,76% za nikosulfuron, 97,88 do 99,17% za rimsulfuron i od 97,91 do 99,83% za prosulfuron. Granice odredivanja za nikosulfuron, rimsulfuron i prosulfuron su bile 0,95, 0,91 i 0,89 [micro]g [kg.sup.-1], redom. Tacnost razvijene metode je potvrdena uporednom analizom uz pomoc HPLC u kombinaciji sa masenom detekcijom. Razvijena metoda je koriscena za ispitivanje dinamike rasipanja sulfonilurea herbicida u realnom poljskom ogledu na podrucju Vojvodine. Dobijena vremena poluraspada za preporucenu dozu primene nikosulfurona, rimsulfurona i prosulfurona su bila 0,05, 0,23 i 0,15 dana, redom. Nizak sadrzaj ostataka ispitivanih herbicida i kratko vreme poluraspada u zemljistu sugerisu na smanjen rizik za osetljive rotirajuce useve nakon primene u odgovarajucim dozama. Kljucne reci: Sulfonilurea herbicid * Mikrotalasna ekstrakcija * HPLC-UV-DAD * Zemljiste
Sprache
Englisch
Identifikatoren
ISSN: 0367-598X
eISSN: 2217-7426
DOI: 10.2298/HEMIND160224039G
Titel-ID: cdi_gale_infotracmisc_A518588015

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX