Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 22

Details

Autor(en) / Beteiligte
Titel
Portable X-ray fluorescence
Ist Teil von
  • PloS one, 2022-01, Vol.17 (1), p.e0262460
Ort / Verlag
Public Library of Science
Erscheinungsjahr
2022
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • With the increasing popularity of local blending of fertilisers, the fertiliser industry faces issues regarding quality control and fertiliser adulteration. Another problem is the contamination of fertilisers with trace elements that have been shown to subsequently accumulate in the soil and be taken up by plants, posing a danger to the environment and human health. Conventional characterisation methods necessary to ensure the quality of fertilisers and to comply with local regulations are costly, time consuming and sometimes not even accessible. Alternatively, using a wide range of unamended and intentionally amended fertilisers this study developed empirical calibrations for a portable handheld X-ray fluorescence (pXRF) spectrometer, determined the reliability for estimating the macro and micro nutrients and evaluated the use of the pXRF for the high-throughput detection of trace element contaminants in fertilisers. The models developed using pXRF for Mg, P, S, K, Ca, Mn, Fe, Zn and Mo had R.sup.2 values greater or equal to 0.97. These models also performed well on validation, with R.sup.2 values greater or equal to 0.97 (except for Fe, R.sup.2 .sub.val = 0.55) and slope values ranging from 0.81 to 1.44. A second set of models were developed with a focus on trace elements in amended fertilisers. The R.sup.2 values of calibration for Co, Ni, As, Se, Cd and Pb were greater than or equal to 0.80. At concentrations up to 1000 mg kg.sup.-1, good validation statistics were also obtained; R.sup.2 values ranged from 0.97-0.99, except in one instance. The regression coefficients of the validation also had good prediction in the range of 0-100 mg kg.sup.-1 (R.sup.2 values were from 0.78-0.99), but not as well at lower concentrations up to 20 mg kg.sup.-1 (R.sup.2 values ranged from 0.10-0.99), especially for Cd. This study has demonstrated that pXRF can measure several major (P, Ca) and micro (Mn, Fe, Cu) nutrients, as well as trace elements and potential contaminants (Cr, Ni, As) in fertilisers with high accuracy and precision. The results obtained in this study is good, especially considering that loose powders were scanned for a maximum of 90 seconds without the use of a vacuum pump.
Sprache
Englisch
Identifikatoren
ISSN: 1932-6203
eISSN: 1932-6203
DOI: 10.1371/journal.pone.0262460
Titel-ID: cdi_gale_incontextgauss_ISR_A689273383

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX