Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 86
Journal of Clinical Microbiology, 2009-12, Vol.47 (12), p.4037-4042
2009

Details

Autor(en) / Beteiligte
Titel
International External Quality Assurance for Laboratory Diagnosis of Diphtheria
Ist Teil von
  • Journal of Clinical Microbiology, 2009-12, Vol.47 (12), p.4037-4042
Ort / Verlag
Washington, DC: American Society for Microbiology
Erscheinungsjahr
2009
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX