Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 26
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2022-01, Vol.1021, Article 165933
2022

Details

Autor(en) / Beteiligte
Titel
Position resolution with 25µm pitch pixel sensors before and after irradiation
Ist Teil von
  • Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2022-01, Vol.1021, Article 165933
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2022
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 × 1016cm−2 1MeV neutron equivalent at 3.0cm distance from the beam are expected for an integrated luminosity of 3000fb−1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiments’ needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100 × 25µm2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to ϕeq=3.6×1015 cm−2. The measurements were performed with a 5GeV electron beam. A spatial resolution of 3.2±0.1µm is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0±0.2µm for a proton-irradiated sensor at ϕeq=2.1×1015 cm−2 and a neutron-irradiated sensor at ϕeq=3.6×1015 cm−2. The extrapolated resolution to infinite beam momentum, where the contribution of multiple scattering can be neglected, has also been evaluated.
Sprache
Englisch
Identifikatoren
ISSN: 0168-9002
eISSN: 1872-9576
DOI: 10.1016/j.nima.2021.165933
Titel-ID: cdi_elsevier_sciencedirect_doi_10_1016_j_nima_2021_165933

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX