Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
International journal of heat and mass transfer, 2024-06, Vol.225, p.125401, Article 125401
2024
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Effect of off-bottom clearance of Lightnin impeller on heat transfer performance in the stirred tank coupled with draft tube
Ist Teil von
  • International journal of heat and mass transfer, 2024-06, Vol.225, p.125401, Article 125401
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2024
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •Heat transfer performance of a Lightnin stirred reactor coupled with draft tube has been investigated.•The optimized impeller off-bottom clearance has been obtained in the draft tube stirred tank.•The time-correlation variation of heating rate and synergistic angle has been investigated.•A correlation formula coupled by multifactor for enhancing heat transfer in a stirred tank has been proposed. The heat transfer issue in stirred tanks is a prevalent concern in the industry. This article aims to investigate the fluid flow and heat transfer within a stirred tank equipped with a Lightnin A320 impeller coupled with a draft tube (DT) structure. The heat transfer performance of a 37 L jacket stirred tank is experimentally measured with the rotation speeds of 50 ‒ 300 RPM. The effects of off-bottom clearances and rotational speeds on mixing and heat transfer performance are explored using Computational Fluid Dynamics (CFD) by flow patterns, local velocity, turbulent kinetic energy (TKE), helicity, vorticity, heat transfer coefficient, synergy angle, extensional efficiency, and coefficient of variation (CoV), respectively. The numerically predicted temperature curves have a good agreement with the experimental results. An optimal off-bottom clearance with C/D = 0.43 is found in this stirred tank. Furthermore, empirical correlations are developed to predict heat transfer performance by analyzing the relationship between wall heat transfer coefficient, power consumption, and heat transfer rate. By evaluating the variation of the temperature gradient synergy angle with time and rotational speed of the stirred tank, it was determined that a stabilization time of 120 s is required for the synergy angle. In the area outside the DT, 80 % of the region exhibits extensional efficiency values greater than 0.5. For 100 ‒ 300 RPM, achieving a CoV of 0.01 requires 48.36 %, 67.26 %, 76.81 %, 82.34 %, and 85.67 % less time compared to that of 50 RPM, respectively. [Display omitted]
Sprache
Englisch
Identifikatoren
ISSN: 0017-9310
eISSN: 1879-2189
DOI: 10.1016/j.ijheatmasstransfer.2024.125401
Titel-ID: cdi_elsevier_sciencedirect_doi_10_1016_j_ijheatmasstransfer_2024_125401

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX