Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 2

Details

Autor(en) / Beteiligte
Titel
Multicenter Core Laboratory Comparison of the Instantaneous Wave-Free Ratio and Resting P d /P a With Fractional Flow Reserve
Ist Teil von
  • Journal of the American College of Cardiology, 2014-04, Vol.63 (13), p.1253-1261
Erscheinungsjahr
2014
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Objectives This study sought to examine the diagnostic accuracy of the instantaneous wave-free ratio (iFR) and resting distal coronary artery pressure/aortic pressure (P d /P a ) with respect to hyperemic fractional flow reserve (FFR) in a core laboratory–based multicenter collaborative study. Background FFR is an index of the severity of coronary stenosis that has been clinically validated in 3 prospective randomized trials. iFR and P d /P a are nonhyperemic pressure-derived indices of the severity of stenosis with discordant reports regarding their accuracy with respect to FFR. Methods iFR, resting P d /P a , and FFR were measured in 1,768 patients from 15 clinical sites. An independent physiology core laboratory performed blinded off-line analysis of all raw data. The primary objectives were to determine specific iFR and P d /P a thresholds with ≥90% accuracy in predicting ischemic versus nonischemic FFR (on the basis of an FFR cut point of 0.80) and the proportion of patients falling beyond those thresholds. Results Of 1,974 submitted lesions, 381 (19.3%) were excluded because of suboptimal acquisition, leaving 1,593 for final analysis. On receiver-operating characteristic analysis, the optimal iFR cut point for FFR ≤0.80 was 0.90 (C statistic: 0.81 [95% confidence interval: 0.79 to 0.83]; overall accuracy: 80.4%) and for P d /P a was 0.92 (C statistic: 0.82 [95% confidence interval: 0.80 to 0.84]; overall accuracy: 81.5%), with no significant difference between these resting measures. iFR and P d /P a had ≥90% accuracy to predict a positive or negative FFR in 64.9% (62.6% to 67.3%) and 48.3% (45.6% to 50.5%) of lesions, respectively. Conclusions This comprehensive core laboratory analysis comparing iFR and P d /P a with FFR demonstrated an overall accuracy of ∼80% for both nonhyperemic indices, which can be improved to ≥90% in a subset of lesions. Clinical outcome studies are required to determine whether the use of iFR or P d /P a might obviate the need for hyperemia in selected patients.
Sprache
Englisch
Identifikatoren
ISSN: 0735-1097
eISSN: 1558-3597
DOI: 10.1016/j.jacc.2013.09.060
Titel-ID: cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0735109713057501
Format
Schlagworte
Cardiovascular, Internal Medicine

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX