Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 35

Details

Autor(en) / Beteiligte
Titel
Impact of blood products on platelet function in patients with traumatic injuries: a translation study
Ist Teil von
  • The Journal of surgical research, 2017-06
Erscheinungsjahr
2017
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Abstract Background Reductions in platelet (PLT) count and function are associated with poor outcomes in trauma patients. We proposed to determine if patients expected to receive blood products have a decrease in PLT function higher than expected based on the reduction in PLT count, and if the reduction in function could be associated with the donor plasma/supernatant received. Methods PLT count and function were measured on admission to the emergency department and intensive care unit in severely injured patients expected to receive a transfusion. PLT function was measured by Multiplate aggregometry in response to five agonists. Function was corrected for alterations in count. In vitro studies were conducted in the blood of normal subjects to assess the effect of dilutions with AB donor plasma on PLT function. Results Forty-six patients were enrolled, with 87% requiring a transfusion. Median Injury Severity Score was 23 (13.29) and mortality 15%. PLT count and function were decreased from emergency department to intensive care unit admission by 25% and 58%, respectively. Decreases in function persisted after adjustment for count. Patients requiring large volumes of blood products had reductions in function that were disproportionately greater. Reductions in PLT function were greatest after transfusion of PLTs. In in vitro studies with a 30% dilution by autologous plasma caused a relational reduction in function, whereas allogenic plasma resulted in greater decreases that were highly variable between donors. Conclusions Within hours of injury a decrease in both PLT count and function occurs, that is aggravated with the administration of blood products, with transfusion of PLTs showing the greatest effect. The effect on PLT function of allogenic transfused plasma appears to be highly donor related.
Sprache
Englisch
Identifikatoren
ISSN: 0022-4804
eISSN: 1095-8673
DOI: 10.1016/j.jss.2017.02.037
Titel-ID: cdi_elsevier_clinicalkeyesjournals_1_s2_0_S0022480417300847
Format
Schlagworte
Surgery

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX