Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 3

Details

Autor(en) / Beteiligte
Titel
An in-silico quality assurance study of contouring target volumes in thoracic tumors within a cooperative group setting
Ist Teil von
  • Clinical and translational radiation oncology, 2019-02, Vol.15, p.83-92
Ort / Verlag
Ireland: Elsevier B.V
Erscheinungsjahr
2019
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • [Display omitted] •We aimed at quantifying inter-observer Pancoast tumors delineation variability.•Experts’ delineations were used to define ground truth.•Other observers’ delineations were compared against ground truth.•High degree of variability was noted for most target volumes except GTV_P.•This unveils potentials for protocol modification for future IMRT studies. Target delineation variability is a significant technical impediment in multi-institutional trials which employ intensity modulated radiotherapy (IMRT), as there is a real potential for clinically meaningful variances that can impact the outcomes in clinical trials. The goal of this study is to determine the variability of target delineation among participants from different institutions as part of Southwest Oncology Group (SWOG) Radiotherapy Committee’s multi-institutional in-silico quality assurance study in patients with Pancoast tumors as a “dry run” for trial implementation. CT simulation scans were acquired from four patients with Pancoast tumor. Two patients had simulation 4D-CT and FDG-FDG PET-CT while two patients had 3D-CT and FDG-FDG PET-CT. Seventeen SWOG-affiliated physicians independently delineated target volumes defined as gross primary and nodal tumor volumes (GTV_P & GTV_N), clinical target volume (CTV), and planning target volume (PTV). Six board-certified thoracic radiation oncologists were designated as the ‘Experts’ for this study. Their delineations were used to create a simultaneous truth and performance level estimation (STAPLE) contours using ADMIRE software (Elekta AB, Sweden 2017). Individual participants’ contours were then compared with Experts’ STAPLE contours. When compared to the Experts’ STAPLE, GTV_P had the best agreement among all participants, while GTV_N showed the lowest agreement among all participants. There were no statistically significant differences in all studied parameters for all TVs for cases with 4D-CT versus cases with 3D-CT simulation scans. High degree of inter-observer variation was noted for all target volume except for GTV_P, unveiling potentials for protocol modification for subsequent clinically meaningful improvement in target definition. Various similarity indices exist that can be used to guide multi-institutional radiotherapy delineation QA credentialing.
Sprache
Englisch
Identifikatoren
ISSN: 2405-6308
eISSN: 2405-6308
DOI: 10.1016/j.ctro.2019.01.001
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_fdbeec815fa241a584403517dfdc590d

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX