Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 23

Details

Autor(en) / Beteiligte
Titel
A Robust Calibration Method for Continental‐Scale Soil Water Content Measurements
Ist Teil von
  • Vadose zone journal, 2018, Vol.17 (1), p.1-19
Ort / Verlag
Madison: The Soil Science Society of America, Inc
Erscheinungsjahr
2018
Quelle
Wiley Online Library Journals Frontfile Complete
Beschreibungen/Notizen
  • Core Ideas We present a semiautomated framework for large‐scale calibration of capacitance soil moisture sensors. Soil‐specific calibrations are needed for accurate moisture measurements in nearly all soil types. Transparent, traceable, and complete uncertainty estimates provided for entire approach. Technological advances have allowed in situ monitoring of soil water content in an automated manner. These advances, along with an increase in large‐scale networks monitoring soil water content, stress the need for a robust calibration framework that ensures that soil water content measurements are accurate and reliable. We have developed an approach to make consistent and comparable soil water content sensor calibrations across a continental‐scale network in a production framework that incorporates a thorough accounting of uncertainties. More than 150 soil blocks of varying characteristics from 33 locations across the United States were used to generate soil‐specific calibration coefficients for a capacitance sensor. We found that the manufacturer's nominal calibration coefficients poorly fit the data for nearly all soil types. This resulted in negative (91% of samples) and positive (5% of samples) biases and a mean root mean square error (RMSE) of 0.123 cm3 cm−3 (1σ) relative to reference standard measurements. We derived soil‐specific coefficients, and when used with the manufacturer's nominal function, the biases were corrected and the mean RMSE dropped to ±0.017 cm3 cm−3 (±1σ). A logistic calibration function further reduced the mean RMSE to ±0.016 cm3 cm−3 (±1σ) and increased the range of soil moistures to which the calibration applied by 18% compared with the manufacturer's function. However, the uncertainty of the reference standard was notable (±0.022 cm3 cm−3), and when propagated in quadrature with RMSE estimates, the combined uncertainty of the calibrated volumetric soil water content values increased to ±0.028 cm3 cm−3 regardless of the calibration function used.
Sprache
Englisch
Identifikatoren
ISSN: 1539-1663
eISSN: 1539-1663
DOI: 10.2136/vzj2017.10.0177
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_f693179fd5794bbca4a3660266e0b7a8

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX