Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 6 von 81

Details

Autor(en) / Beteiligte
Titel
Comparative Study of 2D Petrographic and 3D X-ray Tomography Investigations of Air Voids in Asphalt
Ist Teil von
  • Materials, 2023-02, Vol.16 (3), p.1272
Ort / Verlag
Switzerland: MDPI AG
Erscheinungsjahr
2023
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Knowledge of the exact composition of building materials (aggregate, binder, air voids, etc.) is essential for the further development of more resistant and sustainable building materials. In numerous scientific studies, the material behavior of asphalt is tested using mechanical methods. Here, the overall material behavior is determined (bitumen, air voids, aggregate). With the advent of imaging techniques, it is becoming possible to determine the individual constituents separately and perform a more detailed analysis of their location, shape and composition. Three-dimensional and two-dimensional methods are available for this purpose. For this study, two different types of asphalt (porous asphalt and asphalt concrete) were analyzed using 3D X-ray computed tomography and asphalt petrology as 2D methods; the results of both investigations are compared. The objective of this study is to determine whether the 2D method provides suitable results for the microstructural analysis of asphalt samples and how the results differ from those studied by the 3D method. The comparison shows that both methods can be used to analyze voids in asphalt samples. The 2D method provides valuable insight into the distribution of voids in a sample. In addition to the distribution of voids within a 2D section, the 2D method can also be used to make some structural statements about the location and structure of the voids in the 2D plane. The X-ray computed tomography method allows more complex analyses of the pore structure because of the third direction (3D). In addition, the 3D method provides more data, so that the pore structure can be described even more precisely, and the pore size (length, width, height) can be mapped and analyzed with a high degree of accuracy.
Sprache
Englisch
Identifikatoren
ISSN: 1996-1944
eISSN: 1996-1944
DOI: 10.3390/ma16031272
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_ee0ffc77922742b69a6c4120c556e45d

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX