The influence of reference electrode in electrical impedance tomography
Ist Teil von
  • Heliyon, 2022-12, Vol.8 (12), p.e12454-e12454, Article e12454
Ort / Verlag
England: Elsevier Ltd
Erscheinungsjahr
2022
Quelle
Electronic Journals Library
Beschreibungen/Notizen
  • Some electrical impedance tomography (EIT) devices equip reference electrodes. In practice, it is not uncommon to observe high contact impedance for the reference electrode. The influence of bad contact reference electrode on data quality is unknown. The study aimed to investigate the influence of reference electrode on EIT image reconstruction. Thirty lung healthy volunteers were prospectively examined with EIT. The subjects were spontaneously breathing in supine position. Three scenarios were constructed: 1. Normal measurement; 2. Reference electrode disconnected without recalibration; 3. Reference electrode disconnected, and the measurement restarted after recalibration of the system. EIT-based parameters measuring spatial and temporal ventilation distributions were calculated and compared. A so-call deviation score was calculated to assess the differences in EIT parameters between scenarios 2 and 1, between 3 and 1. The absolute differences for all parameters were significantly higher than zero (p < 0.01 for all parameters and scenarios). Deviation score for scenario 2 was 4.5 ± 3.5. Four subjects had a deviation score of 0 in scenario 2 and five subjects had a score of 1. The deviation in scenario 3 was higher (6.1 ± 3.1). No subjects had a score of 0 and only two subjects had a score of 1. For EIT systems that equips with reference electrode, it is important to ensure the proper contact and functionality of the reference electrode. The EIT data quality would remain unchanged in only a small portion of subjects. Electrical impedance tomography; Reference electrode; Center of ventilation; Regions of interest; Respiratory rate; Global inhomogeneity index; Regional ventilation delay.
Sprache
Englisch
Identifikatoren
ISSN: 2405-8440
eISSN: 2405-8440
DOI: 10.1016/j.heliyon.2022.e12454
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_ec132f70d6824c12a054d3dbf6fced16

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX