Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 540

Details

Autor(en) / Beteiligte
Titel
Ti6Al4V biomimetic scaffolds for bone tissue engineering: Fabrication, biomechanics and osseointegration
Ist Teil von
  • Materials & design, 2023-10, Vol.234, p.112330, Article 112330
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • [Display omitted] •The relationship between biomechanics and porosity and pore size of Ti6Al4V scaffolds was revealed.•Increasing porosity and pore size enhanced the permeability of the trabecular scaffolds but reduced shear stress.•The scaffolds (porosity: 55%∼65%, pore size: 550∼650um) had the best effect on inducing osteogenic differentiation. The design of porous structure that mimic trabecular bone is an effective method for optimizing the elastic modulus and osseointegration properties of titanium alloy implants. However, there is no consensus on which structure is best. In this study, we fabricated 24 different types of Ti6Al4V trabecular bone scaffolds with varying porosity and average pore size using Voronoi algorithm and selective laser melting technology. The biomechanics and osseointegration properties were studied by mechanical tests, computational fluid dynamics, cell and animal experiments. Our results showed that with an increase of porosity and average pore size, the scaffold's yield strength, ultimate strength, elastic modulus and shear stress exhibited an overall decreasing trend while the permeability and nutrient transport improved. Cell experiments showed that reducing the average pore size enhanced the adhesion and proliferation of MC3T3-E1 cells when the porosity was constant. Animal experiments showed that the scaffold with 65% porosity and 550 μm pore size had the most significant new bone formation effect. Based on our research results, we concluded that a porous structure design with 65% porosity and an average pore size of 550 μm, resembling bone trabecular, had the most significant effect on enhancing the comprehensive performance of titanium alloy implants.
Sprache
Englisch
Identifikatoren
ISSN: 0264-1275
eISSN: 1873-4197
DOI: 10.1016/j.matdes.2023.112330
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_ea74f254fd874d9a83a2b69eff76f45b

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX