Ex vivo electrochemical measurement of glutamate release during spinal cord injury
Ist Teil von
MethodsX, 2019-01, Vol.6, p.1894-1900
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2019
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
[Display omitted]
Excessive glutamate release following traumatic spinal cord injury (SCI) has been associated with exacerbating the extent of SCI. However, the mechanism behind sustained high levels of extracellular glutamate is unclear. Spinal cord segments mounted in a sucrose double gap recording chamber are an established model for traumatic spinal cord injury. We have developed a method to record, with micro-scale printed glutamate biosensors, glutamate release from ex vivo rat spinal cord segments following injury. This protocol would work equally well for similar glutamate biosensors.