Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 600

Details

Autor(en) / Beteiligte
Titel
New Approaches for Prediction of Flow Regime Boundaries and Overall Gas Holdups in a Bubble Column Operated with Aqueous Solutions of 2-Pentanol
Ist Teil von
  • Journal of chemical engineering of Japan, 2024-12, Vol.57 (1)
Ort / Verlag
Taylor & Francis Group
Erscheinungsjahr
2024
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • AbstractThe article reports a new approach for flow regime (FR) identification and a modified correlation for gas holdup prediction in a bubble column (BC) (0.1 m inner diameter) operated with aqueous solutions of 2-pentanol at ambient conditions. The hydrodynamic behavior of mixtures of deionized water (DW) and 2-pentanol with different volume concentrations (0.5 − 2.0 vol.%) was examined. A new algorithm for estimation of the information amount (IA) from a gauge pressure (GP) signal is proposed. It is based on simultaneous statistical and error analyses of the sub-divided GP time series. The new approach extracts detailed hidden information from every sector of the time-dependent GP signal. In case of 0.5 vol.% 2-pentanol dissolved in DW, by means of the local well-pronounced IA minima, three transition velocities Utrans (at 0.043, 0.054 and 0.073 m/s) were reliably identified. The first critical velocity was comparable with the prediction of a well-known empirical correlation. When the volume concentration of 2-pentanol in DW was doubled, then the three Utrans values were distinguished at 0.049, 0.063 and 0.074 m/s, respectively. In addition, the end of the gas maldistribution state was identified at 0.041 m/s. It was found that the increase of the alcohol concentration affects the first and second Utrans values but not the third one, i.e. the onset of the complete foaming state. The overall gas holdups were also successfully predicted in both homogeneous and transition flow regimes of BC operation. One of the parameters (taking part in a dimensionless group about the scale effect) in an existing empirical correlation was modified in order to predict the overall gas holdups recorded in different aqueous solutions of 2-pentanol. The modified parameter was fitted for every mixture investigated. The average relative error was reasonably low in every case.
Sprache
Englisch
Identifikatoren
ISSN: 0021-9592
eISSN: 1881-1299
DOI: 10.1080/00219592.2024.2330388
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_c99bd72302734911af6dcb3f080bf0ce

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX