Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 21 von 32

Details

Autor(en) / Beteiligte
Titel
Evolução da onda P do eletrocardiograma após valvoplastia mitral em pacientes portadores de sobrecarga atrial esquerda Changes in P-wave after percutaneous mitral valvuloplasty in patients with mitral stenosis and left atrial enlargement
Ist Teil von
  • Arquivos brasileiros de cardiologia, 2006-09, Vol.87 (3), p.359-363
Ort / Verlag
Sociedade Brasileira de Cardiologia (SBC)
Erscheinungsjahr
2006
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • OBJETIVO: Investigar potenciais preditores clínicos, ecocardiográficos e/ou hemodinâmicos de regressão de sinais eletrocardiográficos (ECG) de sobrecarga atrial esquerda (SAE) após valvoplastia mitral percutânea (VMP) com sucesso. MÉTODOS: Estudaram-se 24 pacientes (75% do sexo feminino, idade média 37,1 ± 11,9 anos) com estenose mitral moderada a grave, ritmo sinusal (RS) e sinais de SAE no ECG, submetidos a VMP entre 2002 e 2004. Pelo menos seis meses após o procedimento (388,2 ± 192,9 dias), os pacientes retornaram para acompanhamento clínico, eletro e ecocardiográfico. Os pacientes foram divididos em dois grupos: Grupo 1(n = 8; 33,3%), ainda com sinais ECG de SAE, e Grupo 2 (n = 16; 66,6%), com onda P normal. Realizou-se análise multivariada de variáveis clínicas, ECG, ecocardiográficas e hemodinâmicas. RESULTADOS: A área valvar mitral (AVM) aumentou de 1,12 ± 0,15 para 1,9 ± 0,35cm² imediatamente após o procedimento (p< 0,0001), e diminuiu para 1,89 ± 0,41cm² no acompanhamento (p = NS). O diâmetro do átrio esquerdo variou de 4,8 ± 0,29 cm pré-procedimento para 4,28 ± 0,48cm na reavaliação (p = 0,0001). A duração da onda P diminuiu de 0,12 ± 0,01 seg pré-VMP para 0,09 ± 0,02 seg no controle (p = 0,0001). Uma AVM > 1,7 cm² no acompanhamento foi o único preditor independente de onda P normal após VMP (p = 0,02). CONCLUSÃO: Alterações ECG sugestivas de SAE regridem na maioria dos pacientes com estenose mitral e RS submetidos a VMP com sucesso. Uma AVM > 1,7 cm² no controle tardio é preditor independente para essa normalização.OBJECTIVE: To investigate potential clinical, echocardiographic and/or hemodynamic predictors of the regression of electrocardiographic (ECG) signs of left atrial enlargement (LAE) after successful percutaneous mitral valvuloplasty (PMV). METHODS: We studied 24 patients (75% female, mean age =37.1 ± 11.9 years) with moderate to severe mitral stenosis (MS), sinus rhythm (SR) and ECG signs of LAE who underwent successful PMV between 2002 and 2004. At least 6 months after the procedure (388.2 ± 192.9 days), the patients returned for clinical, ECG and echocardiographic follow-up. They were then divided in 2 groups: patients of group 1 (n = 8; 33.3%) still had ECG signs of LAE, and patients of group 2 (n = 16; 66.6%), had normal P wave. A multivariate analysis of clinical, ECG, echocardiographic and hemodynamic variables was performed. RESULTS: The mitral valve area (MVA) increased from 1.12 ± 0.15 cm2 to 1.9 ± 0.35 cm² immediately after the procedure (p < 0.0001) and decreased to 1.89 ± 0.41 cm² at follow-up (p = NS). Left atrium diameter decreased from 48 ± 2.9mm pre-procedure to 43 ± 4.8mm at follow-up (p = 0.0001). P-wave duration decreased from 0.12 ± 0.01 sec pre-PMV to 0.09 ± 0.02 sec at follow-up (p = 0.0001). An MVA > 1.7 cm² at follow-up was the only independent predictor of a normal P-wave after PMV (p=0.02). CONCLUSION: ECG changes suggestive of LAE regress in the majority of patients with MS and sinus rhythm that undergo a successful PMV. An MVA>1.7 cm² at late follow-up was found to be an independent predictor of such normalization.
Sprache
Englisch
Identifikatoren
ISSN: 0066-782X
eISSN: 1678-4170
DOI: 10.1590/S0066-782X2006001600020
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_c02be0629d3a4d628dd586568bc6965e

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX