Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 80

Details

Autor(en) / Beteiligte
Titel
Electrocardiographic Detection of Left Ventricular Hypertrophy; Adding Body Mass Index and Spatial QRS-T Angle: A Cross-Sectional Study
Ist Teil von
  • Cardiology and therapy, 2019-12, Vol.8 (2), p.345-356
Ort / Verlag
Cheshire: Springer Healthcare
Erscheinungsjahr
2019
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Introduction We investigated improvement of electrocardiographic LVH detection by adding measures of adiposity and/or novel electrocardiographic measures. Left ventricular hypertrophy (LVH) is an important risk factor for adverse cardiovascular outcomes. Improvement of electrocardiographic criteria for LVH is desirable, since electrocardiography is widely used. Methods We included 1091 participants of the Netherlands Epidemiology of Obesity Study (NEO) who underwent cardiac magnetic resonance imaging (MRI). Performance of Sokolow–Lyon and Cornell voltage and product criteria was assessed. Stepwise regression analysis was performed with each conventional electrocardiographic criterion and age, sex, body mass index (BMI), waist circumference, and waist:hip ratio ( p -entry < 0.05, p -removal > 0.10). T-wave abnormalities or the spatial QRS-T angle (SA) were added to the improved models. Results The study population had a mean (SD) age of 56 (6) years, BMI of 26.1 (4.0) kg/m 2 and 46% were men. MRI-LVH was present in 10% of participants. The c -statistic for Sokolow–Lyon voltage was 0.58, R 2 was 0.02 and sensitivity at 90% specificity was 16%, for Sokolow–Lyon product this was 0.62, 0.02, and 21%, for Cornell voltage 0.65, 0.04, and 28% and for Cornell product 0.67, 0.04, and 25%. Best performing models were obtained by addition of both BMI and SA (Sokolow-Lyon voltage: c -statistic 0.74, R 2 0.11, sensitivity of 41% at 90% specificity; Sokolow-Lyon product: 0.75, 0.12, 42%; Cornell voltage: c -statistic 0.70, R 2 0.08, sensitivity of 38% at 90% specificity; Cornell product: c -statistic 0.72, R 2 0.08, sensitivity of 44% at 90% specificity). Conclusions Electrocardiographic detection of LVH improved by adding BMI and SA to a model with conventional electrocardiographic criteria. This approach would require little extra effort and application in clinical practice is feasible. However, results should first be replicated in high-risk populations.
Sprache
Englisch
Identifikatoren
ISSN: 2193-8261
eISSN: 2193-6544
DOI: 10.1007/s40119-019-00151-9
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_b9e05de3c41048fabb008d5a78d6b179

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX