Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 154
Journal of Biomechanical Science and Engineering, 2023, Vol.18(1), pp.22-00276-22-00276
2023
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Numerical simulation to evaluate guidewire and catheter behavior during catheter introduction
Ist Teil von
  • Journal of Biomechanical Science and Engineering, 2023, Vol.18(1), pp.22-00276-22-00276
Ort / Verlag
Tokyo: The Japan Society of Mechanical Engineers
Erscheinungsjahr
2023
Quelle
EZB Free E-Journals
Beschreibungen/Notizen
  • A national questionnaire survey on guidewire penetration accidents by the Japanese Society for Neuroendovascular Therapy reported examples of perforation accidents occurring “during catheter introduction” (75.2% of accidents). In this study, we evaluated the behavior of a guidewire and a catheter during catheter introduction by numerical simulations, based on the results of the national survey. Using the contact force between the medical devices and the vessel wall, and the medical device position as criteria, we investigated the mechanism and the risk of penetration by the device tip during device introduction. We also evaluated the effects of the insertion velocity of the guidewire and the catheter. The contact force gradually increased during insertion of the guidewire, and the maximum contact force was observed after the guidewire passed through a bend in the blood vessel. After that, when introducing a catheter along the guidewire at the bend in the blood vessel, the guidewire imparted a greater load on the vessel wall than when the guidewire itself was introduced. This is the same tendency seen in our previous study and the national survey. One reason for the force increase during catheter introduction is a decrease in the contact area, which concentrates the contact force. Another reason for the force increase is that the bending stiffness of the guidewire covered by the catheter is the sum of the stiffnesses of the two devices, which is larger than that of only the guidewire. Different from guidewire introduction, as the insertion velocity of the catheter increased, the maximum contact force decreased under the influence of the bend shape and the contact force distribution. Moreover, the guidewire oscillated considerably when the catheter was introduced, and this oscillation increased as the insertion velocity increased, leading to a risk of mistakenly straying into a perforating branch.
Sprache
Englisch
Identifikatoren
ISSN: 1880-9863
eISSN: 1880-9863
DOI: 10.1299/jbse.22-00276
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_b29c2d0f52664229a1c26c66c6791096

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX