Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 22

Details

Autor(en) / Beteiligte
Titel
Diagnostic value of congenital pulmonary airway malformation volume ratio for fetal hydrops due to congenital lung malformations: a systematic review and meta-analysis
Ist Teil von
  • Orphanet journal of rare diseases, 2022-06, Vol.17 (1), p.213-213, Article 213
Ort / Verlag
England: BioMed Central Ltd
Erscheinungsjahr
2022
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Meta-analysis was used to evaluate the diagnostic value of a CVR cut-off value of 1.6 for fetal hydrops due to congenital lung malformation (CLM). A systematic search of PubMed, Embase, Web of Science, CNKI, VIP, and Wanfang published before 7/30/2021 for the value of a congenital pulmonary airway malformation volume ratio (CVR) cut-off value of 1.6 for the diagnosis of fetal hydrops. According to the inclusion and exclusion criteria, the literature that met the requirements were obtained. A total of 75 articles were retrieved, and 12 articles were included for further analysis. The quality of these studies was evaluated according to the Quality Assessment for Studies of Diagnostic Accuracy tool (QUADAS-2) criteria. The Q test and heterogeneity I were used to evaluate the heterogeneity due to non-threshold effects, and Stata 15.0 was used for statistical analysis to evaluate the diagnostic value of the CVR cutoff value of 1.6 for fetal hydrops due to CLM. A total of 12 studies were included. The QUADAS-2 indicated that the risk of bias was relatively low, and the clinical applicability was relatively high. Statistical analysis was performed on included studies using a random effect model. Meta-analysis showed that the pooled sensitivity, specificity, diagnostic ratio and summary receiver operating characteristic (SROC) for the diagnosis of fetal hydrops by CVR were 0.86 (95% CI, 0.72-0.93; I  = 59.84), 0.90 (95% CI, 0.88-0.93; I  = 31.94), 58 (95% CI, 22-149; I  = 100%), 0.93 (95% CI, 0.91-0.95). The sensitivity and specificity of CVR cut-off value 1.6 for the diagnosis of CLM-induced fetal hydrops were high, no publication bias was observed, and the CVR cut-off value 1.6 is meaningful for the early diagnosis prediction of CLM-induced fetal hydrops.
Sprache
Englisch
Identifikatoren
ISSN: 1750-1172
eISSN: 1750-1172
DOI: 10.1186/s13023-022-02347-0
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_adb2f52a359a4f0eaa7ac53128f31880

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX