P24 Brachial and Central Systolic Blood Pressures from Two Oscillometric Devices (Sphygmocor and Mobil-O-Graph) Overestimate High Fidelity Intra-Arterial Measurements in Children and Adolescents: Results of the Kidcorebp Study
Ist Teil von
  • Artery research, 2018-12, Vol.24 (1), p.86-87
Ort / Verlag
Dordrecht: Springer Netherlands
Erscheinungsjahr
2018
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Objective This study investigated the accuracy of two oscillometric devices for measuring brachial and central blood pressures (BP) in children and adolescents, using high fidelity intra-arterial measurements as a gold-standard reference. Methods 57 children and adolescents aged 9.5 ± 4.6 years (mean ± SD, range 3 to 17, 74% <13 years) without aortic obstruction were recruited. A catheter was inserted into the ascending aorta via the femoral artery during a clinically-indicated procedure. Aortic BP was measured with a Verrata wire (Philips Volcano), along with brachial BP via two oscillometric devices: SphygmoCor XCEL (AtCor Medical, N = 51) and/or Mobil-o-Graph (MoG, IEMGmbH, N = 40). Intra-arterial brachial systolic BP was derived by calibrating the brachial pulse waveform (measured via tonometry after wire removal) to aortic mean and diastolic BP. For MoG, central pressure was derived through standard systolic-diastolic calibration (MoGC1) as well as mean-diastolic calibration (MoGC2). Results Mean±SD differences between device and intra-arterial BP are presented in the Table. There was moderate correlation between device and intra-arterial brachial systolic BP (R = 0.58 XCEL, R = 0.47 MoG, P < 0.01) and central systolic BP (R = 0.69 XCEL, R = 0.64 MoGC1, R = 0.43 MoGC2, P < 0.01). Intra-arterial central-to-brachial pulse amplification factor was 1.17 ± 0.16 (range 0.88 to 1.55), but there was no correlation between device and intra-arterial amplification (R = 0.07 XCEL, R = 0.07 MoGC1, R = 0.19 MoGC2, P > 0.18). Results in sub-groups >13 and <13 years were similar. Conclusion Both oscillometric devices overestimated brachial and central systolic/pulse BP, exceeding the validation criteria of 5 ± 8 mmHg, and there was no correlation between intra-arterial and device-derived central-to-brachial pulse amplification. Diastolic BP was acceptable. Table Mean+SD of the difference (mmHg) between device and intra-arterial measurements. Systolic Diastolic Pulse Brachial XCEL 11.2 ± 8.9 −1.7 ± 6.0 13.0 ± 10.1 Brachial MoG 12.9 ± 11.7 −4.7 ± 5.4 17.9 ± 11.4 Central XCEL 8.8 ± 6.6 −0.7 ± 6.2 9.0 ± 7.7 Central MoGC1 7.7 ± 10.3 −3.1 ± 6.1 10.6 ± 11.6 Central MoGC2 22.3 ±14.3 −3.2 ± 6.6 25.4 ±15.0
Sprache
Englisch
Identifikatoren
ISSN: 1872-9312, 1876-4401
eISSN: 1876-4401
DOI: 10.1016/j.artres.2018.10.077
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_a82c986451fd4620b6cec81f279c6cc7
Format
Schlagworte
ARTERY 18 Poster Session, Teenagers

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX