Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 3722

Details

Autor(en) / Beteiligte
Titel
Gait Speed Trajectory During the Six-Minute Walk Test in Multiple Sclerosis: A Measure of Walking Endurance
Ist Teil von
  • Frontiers in neurology, 2021-07, Vol.12, p.698599-698599
Ort / Verlag
Frontiers Media S.A
Erscheinungsjahr
2021
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background: The six-minute walk (6MW) test is a validated assessment method in Multiple Sclerosis (MS) research. While the total distance covered during six minutes ( 6MW TD ) is often used as the standard measurement of gait capacity (i.e., the maximum distance one can achieve), we hypothesize that endurance (i.e., ability to maintain speed over a prolonged time) can be inferred by the gait speed trajectory (GST) during the 6MW test ( 6MW GST ). Objective: To characterize group differences in 6MW GST between MS patients and healthy controls (HCs), and to assess information added by 6MW GST for discerning between MS patients and HCs. Methods: We performed a secondary data analysis on a cross-sectional cohort of 40 MS and 20 HC subjects with three repeated 6MW tests. We modeled 6MW GST using a linear mixed-effects model with time in minutes and replicated walks nested within individuals. We compared the discernibility of 6MW GST with that of conventional metrics using likelihood ratio tests and receiver operating characteristic (ROC) analysis on logistic regression models. Results: MS subjects showed a concave, quadratic GST during 6MW tests, slowing down more than the HC subjects, especially at the beginning of 6MW tests. Despite accelerating at the end of the 6MW, MS subjects were unable to attain or surpass their initial 6MW gait speeds. 6MW GST added useful information ( p = 0.002) to the conventional metrics (e.g., 6MW TD ) for discerning between MS and HC subjects, and increased the area under the ROC curve from 0.83 to 0.93 ( p = 0.037). Conclusions: The distinctive 6MW GST pattern of MS patients provided increased discernibility compared with currently used gait metrics. Both gait capacity measured by the 6MW TD , and gait endurance measured by parameters of 6MW GST , are significant functional indicators for the MS population.
Sprache
Englisch
Identifikatoren
ISSN: 1664-2295
eISSN: 1664-2295
DOI: 10.3389/fneur.2021.698599
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_9a8d03494a60465998e20001087a3a1b

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX