Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 125

Details

Autor(en) / Beteiligte
Titel
Chemistry and lung toxicity of particulate matter emitted from firearms
Ist Teil von
  • Scientific reports, 2022-12, Vol.12 (1), p.20722-14, Article 20722
Ort / Verlag
England: Nature Publishing Group
Erscheinungsjahr
2022
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Smoke emissions produced by firearms contain hazardous chemicals, but little is known if their properties change depending on firearm and ammunition type and whether such changes affect toxicity outcomes. Pulmonary toxicity was assessed in mice exposed by oropharyngeal aspiration to six different types of smoke-related particulate matter (PM) samples; (1) handgun PM, (2) rifle PM, (3) copper (Cu) particles (a surrogate for Cu in the rifle PM) with and without the Cu chelator penicillamine, (4) water-soluble components of the rifle PM, (5) soluble components with removal of metal ions, and (6) insoluble components of the rifle PM. Gun firing smoke PM was in the respirable size range but the chemical composition varied with high levels of Pb in the handgun and Cu in the rifle smoke. The handgun PM did not induce appreciable lung toxicity at 4 and 24 h post-exposure while the rifle PM significantly increased lung inflammation and reduced lung function. The same levels of pure Cu particles alone and the soluble components from the rifle fire PM increased neutrophil numbers but did not cause appreciable cellular damage or lung function changes when compared to the negative (saline) control. Penicillamine treated rifle PM or Cu, slightly reduced lung inflammation and injury but did not improve the lung function decrements. Chelation of the soluble metal ions from the rifle fire PM neutralized the lung toxicity while the insoluble components induced the lung toxicity to the same degree as the rifle PM. The results show that different firearm types can generate contrasting chemical spectra in their emissions and that the rifle PM effects were mostly driven by water-insoluble components containing high levels of Cu. These findings provide better knowledge of hazardous substances in gun firing smoke and their potential toxicological profile.
Sprache
Englisch
Identifikatoren
ISSN: 2045-2322
eISSN: 2045-2322
DOI: 10.1038/s41598-022-24856-5
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_7b9e145690aa4cee806c7eca9a4b2eb6

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX