Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 6294

Details

Autor(en) / Beteiligte
Titel
Local control and failure patterns after intensity modulated radiotherapy with reduced target volume delineation after induction chemotherapy for patients with T4 nasopharyngeal carcinoma
Ist Teil von
  • Translational oncology, 2022-02, Vol.16, p.101324-101324, Article 101324
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2022
Quelle
Elektronische Zeitschriftenbibliothek (Open access)
Beschreibungen/Notizen
  • •Induction chemotherapy combined with radiotherapy achieved excellent local control.•In-field recurrence is major local failure pattern for T4 nasopharyngeal carcinoma.•Radiotherapy with reduced target volume after induction chemotherapy is feasible. The delineation of target volume after induction chemotherapy(IC) for nasopharyngeal carcinoma(NPC) is currently controversial. In this study, we aimed to analyze the long-term local control(LC) and failure patterns of T4 NPC treated with reduced target volume radiotherapy after IC. From September 2007 to January 2013, 145 patients with T4 NPC were retrospectively reviewed. All patients received at least 1 cycle of IC followed by intensity modulated radiotherapy(IMRT). The gross tumor volume(GTV) was delineated according to the post-IC images for intracavity tumors and lymph nodes. The LC and overall survival (OS) rates were calculated using the Kaplan-Meier method. The location and extent of local failures were transferred to the pretreatment planning computed tomography (CT) for dosimetric analysis. With a median follow-up time of 95 months (range, 16–142 months), 23 local failures were found. The estimated 10-year LC and OS rates were 81.1%and 54.8% respectively. Among the 20 local failures with available diagnostic images, 18(90%) occurred within the 95% isodose lines and were considered in-field failures and 2(10%) were marginal. There was no outside-field failure. In-field failure was the major pattern of local failure for T4 NPC. IMRT with reduced target volume after IC seems to be feasible. Further researches exploring optimal volume and radiation dose for local advanced NPC in the era of IC are warranted.
Sprache
Englisch
Identifikatoren
ISSN: 1936-5233
eISSN: 1936-5233
DOI: 10.1016/j.tranon.2021.101324
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_6e67d5de1fdf4322a0b3d47e8436de71

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX