Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 115

Details

Autor(en) / Beteiligte
Titel
Cardiac magnetic resonance outperforms echocardiography to predict subsequent implantable cardioverter defibrillator therapies in ST-segment elevation myocardial infarction patients
Ist Teil von
  • Frontiers in cardiovascular medicine, 2023-02, Vol.10, p.991307-991307
Ort / Verlag
Switzerland: Frontiers Media S.A
Erscheinungsjahr
2023
Quelle
EZB-FREE-00999 freely available EZB journals
Beschreibungen/Notizen
  • Implantable cardioverter defibrillators (ICD) are effective as a primary prevention measure of ventricular tachyarrhythmias in patients with ST-segment elevation myocardial infarction (STEMI) and depressed left ventricular ejection fraction (LVEF). The implications of using cardiac magnetic resonance (CMR) instead of echocardiography (Echo) to assess LVEF prior to the indication of ICD in this setting are unknown. We evaluated 52 STEMI patients (56.6 ± 11 years, 88.5% male) treated with ICD in primary prevention who underwent echocardiography and CMR prior to ICD implantation. ICD implantation was indicated based on the presence of heart failure and depressed LVEF (≤ 35%) by echocardiography, CMR, or both. Prediction of ICD therapies (ICD-T) during follow-up by echocardiography and CMR before ICD implantation was assessed. Compared to echocardiography, LVEF was lower by cardiac CMR (30.2 ± 9% vs. 37.4 ± 7.6%, < 0.001). LVEF ≤ 35% was detected in 24 patients (46.2%) by Echo and in 42 (80.7%) by CMR. During a mean follow-up of 6.1 ± 4.2 years, 10 patients received appropriate ICD-T (3.16 ICD-T per 100 person-years): 5 direct shocks to treat very fast ventricular tachycardia or ventricular fibrillation, 3 effective antitachycardia pacing (ATP) for treatment of ventricular tachycardia, and 2 ineffective ATP followed by shock to treat ventricular tachycardia. Echo-LVEF ≤ 35% correctly predicted ICD-T in 4/10 (40%) patients and CMR-LVEF ≤ 35% in 10/10 (100%) patients. CMR-LVEF improved on Echo-LVEF for predicting ICD-T (area under the curve: 0.76 vs. 0.48, = 0.04). In STEMI patients treated with ICD, assessment of LVEF by CMR outperforms Echo-LVEF to predict the subsequent use of appropriate ICD therapies.
Sprache
Englisch
Identifikatoren
ISSN: 2297-055X
eISSN: 2297-055X
DOI: 10.3389/fcvm.2023.991307
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_652b31db0f1b4fdc85f66aebc76a4128

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX