Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 21 von 117

Details

Autor(en) / Beteiligte
Titel
Age-stratified outcomes of bioprosthetic and mechanical aortic valve replacements in an Australian cohort of 13 377 patients
Ist Teil von
  • BMJ surgery, interventions, & health technologies, 2020-10, Vol.2 (1), p.e000036-e000036
Ort / Verlag
England: BMJ Publishing Group Ltd
Erscheinungsjahr
2020
Link zum Volltext
Quelle
EZB Free E-Journals
Beschreibungen/Notizen
  • ObjectivesTo quantify age-stratified outcomes of bioprosthetic valve (BV) and mechanical valve (MV) surgical aortic valve replacement (AVR) in Australian patients.DesignRetrospective cohort study using population-based linked hospital morbidity and mortality data.SettingPublic and private hospitals.ParticipantsPatients aged 18 years and over undergoing AVR from 2001 to 2013, stratified by age (18–64 years; 65+ years).Main outcome measuresAge-standardized index AVR rates; rates and multivariable-adjusted (age, sex, Charlson Comorbidity Index) incidence rate ratios (IRRs) for reoperation, incident cardiovascular events (hospitalization or death for acute myocardial infarction (AMI), stroke, major hemorrhage or thromboembolism) and mortality (cardiovascular and all-cause).ResultsOur cohort comprised 13 377 patients, of whom 3464 (26%) were aged 18–64 years. Annual age-standardized AVR rates increased by 2.7% with BV implants increasing in both age groups. After 5 years of follow-up, patients implanted with BV had lower rates of stroke (IRR: 0.40, 95% CI 0.27 to 0.60) and hemorrhage (IRR: 0.36, 95% CI 0.26 to 0.50). Among patients 65+ years, those implanted with BV had lower rates of AMI, hemorrhage, and cardiovascular and all-cause mortality than those implanted with MV (IRR: 0.71, 95% CI 0.53 to 0.96; IRR: 0.77, 95% CI 0.62 to 0.95; IRR: 0.80, 95% CI 0.69 to 0.92 and IRR: 0.85, 95% CI 0.74 to 0.97, respectively). After 6–10 years of follow-up, reoperation rates among patients 18–64 years were markedly higher in those implanted with BV compared with MV (IRR: 5.48, 95% CI 2.38 to 12.62) and rates of AMI were lower among patients implanted with BV compared with MV (IRR: 0.49, 95% CI 0.26 to 0.94). Among patients 65+ years rates of cardiovascular and all-cause mortality remained significantly lower for patients implanted with BV compared with MV.ConclusionsThis study provides real-world evidence of AVR use and outcomes. Use of BV implants is increasing irrespective of age. Valve choice in younger patients requires thorough evaluation of patient factors influencing both short-term outcomes and longer-term risks of reoperation, stroke and hemorrhage.
Sprache
Englisch
Identifikatoren
ISSN: 2631-4940
eISSN: 2631-4940
DOI: 10.1136/bmjsit-2020-000036
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_530b5b09b2ab4b61ba4ca7f7c29baa69

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX