Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 4 von 54

Details

Autor(en) / Beteiligte
Titel
Refractory ineffective triggering during pressure support ventilation: effect of proportional assist ventilation with load-adjustable gain factors
Ist Teil von
  • Annals of intensive care, 2021-10, Vol.11 (1), p.147-147, Article 147
Ort / Verlag
Cham: Springer International Publishing
Erscheinungsjahr
2021
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Background Ineffective triggering is frequent during pressure support ventilation (PSV) and may persist despite ventilator adjustment, leading to refractory asynchrony. We aimed to assess the effect of proportional assist ventilation with load-adjustable gain factors (PAV+) on the occurrence of refractory ineffective triggering. Design Observational assessment followed by prospective cross-over physiological study. Setting Academic medical ICU. Patients Ineffective triggering was detected during PSV by a twice-daily inspection of the ventilator’s screen. The impact of pressure support level (PSL) adjustments on the occurrence of asynchrony was recorded. Patients experiencing refractory ineffective triggering, defined as persisting asynchrony at the lowest tolerated PSL, were included in the physiological study. Interventions Physiological study: Flow, airway, and esophageal pressures were continuously recorded during 10 min under PSV with the lowest tolerated PSL, and then under PAV+ with the gain adjusted to target a muscle pressure between 5 and 10 cmH 2 O. Measurements Primary endpoint was the comparison of asynchrony index between PSV and PAV+ after PSL and gain adjustments. Results Among 36 patients identified having ineffective triggering under PSV, 21 (58%) exhibited refractory ineffective triggering. The lowest tolerated PSL was higher in patients with refractory asynchrony as compared to patients with non-refractory ineffective triggering. Twelve out of the 21 patients with refractory ineffective triggering were included in the physiological study. The median lowest tolerated PSL was 17 cmH 2 O [12–18] with a PEEP of 7 cmH 2 O [5–8] and FiO 2 of 40% [39–42]. The median gain during PAV+ was 73% [65–80]. The asynchrony index was significantly lower during PAV+ than PSV (2.7% [1.0–5.4] vs . 22.7% [10.3–40.1], p  < 0.001) and consistently decreased in every patient with PAV+. Esophageal pressure–time product (PTPes) did not significantly differ between the two modes (107 cmH 2 O/s/min [79–131] under PSV vs . 149 cmH 2 O/s/min [129–170] under PAV+, p  = 0.092), but the proportion of PTPes lost in ineffective triggering was significantly lower with PAV+ (2 cmH 2 O/s/min [1–6] vs . 8 cmH 2 O/s/min [3–30], p  = 0.012). Conclusions Among patients with ineffective triggering under PSV, PSL adjustment failed to eliminate asynchrony in 58% of them (21 of 36 patients). In these patients with refractory ineffective triggering, switching from PSV to PAV+ significantly reduced or even suppressed the incidence of asynchrony.
Sprache
Englisch
Identifikatoren
ISSN: 2110-5820
eISSN: 2110-5820
DOI: 10.1186/s13613-021-00935-0
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_4b848b0d782742169951d71303a0af4d

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX