Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 115

Details

Autor(en) / Beteiligte
Titel
Effects of overtreatment with different attachment positions on maxillary anchorage enhancement with clear aligners: a finite element analysis study
Ist Teil von
  • BMC oral health, 2023-09, Vol.23 (1), p.1-693, Article 693
Ort / Verlag
London: BioMed Central Ltd
Erscheinungsjahr
2023
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Abstract Background The effect of attachment positions on anchorage has not been fully explored. The aim of the present study is to analyze the effect of overtreatment with different anchorage positions on maxillary anchorage enhancement with clear aligners in extraction cases. Methods Models of the maxilla and maxillary dentition were constructed and imported into SOLIDWORKS software to create periodontal ligament (PDL), clear aligners, and attachments. Attachment positions on second premolars included: without attachment (WOA), buccal attachment (BA), and bucco-palatal attachment (BPA). Overtreatment degrees were divided into five groups (0°, 1°, 2°, 3°, 4°) and added on the second premolars. The calculation and analysis of the displacement trends and stress were performed using ANSYS software. Results Distal tipping and extrusion of the canines, and mesial tipping and intrusion of the posterior teeth occurred during retraction. A strong anchorage was achieved in cases of overtreatment of 2.8° with BA and 2.4° with BPA. Moreover, the BPA showed the best in achieving bodily control of the second premolars. When the overtreatment was performed, the canines and first molars also showed reduced tipping trends with second premolars attachments. And the stress on the PDL and the alveolar bone was significantly relieved and more evenly distributed in the BPA group. Conclusions Overtreatment is an effective means for anchorage enhancement. However, the biomechanical effect of overtreatment differs across attachment positions. The BPA design performs at its best for stronger overtreatment effects with fewer adverse effects.
Sprache
Englisch
Identifikatoren
ISSN: 1472-6831
eISSN: 1472-6831
DOI: 10.1186/s12903-023-03340-0
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_41f484dadc8e427bb6aa67edd35c3e0f

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX