Diagnostic performance of a device for acoustic heart sound analysis in patients with suspected myocardial infarction
Ist Teil von
  • Open heart, 2023-03, Vol.10 (1), p.e002090
Ort / Verlag
England: British Cardiovascular Society
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • BackgroundAs only a small proportion of patients with chest pain suffers from myocardial infarction (MI), safe rule-out of MI is of immense importance. Recently an ultrasensitive microphone performing diastolic heart sound analysis (CADScorSystem) for rule-out of coronary artery disease (CAD) has emerged. In this explorational study, we aimed to evaluate the feasibility of the CADScorSystem for diagnosis of MI in the setting of a large emergency department.MethodsPatients presenting to the emergency department with suspected MI were included. Acoustic heart sound analysis was performed in all patients and automated CAD-score values were calculated via a device-embedded algorithm, which also requires inclusion of three clinical variables: age, sex and presence of hypertension. Patients additionally received serial high-sensitive troponin T measurement measurements to assess the final diagnosis according to third Universal Definition of Myocardial Infarction applying the European Society of Cardiology 0 hour/3 hours algorithm. Diagnostic parameters for MI, considering different CAD-score cut-offs, were computed.ResultsOf 167 patients, CAD-scores were available in 61.1%. A total of eight patients were diagnosed with MI. At a cut-off value of <20, CAD-score had a negative predictive value (NPV) of 90.7 (78.4–96.3). The corresponding positive predictive value (PPV) was 6.8 (2.7–16.2). For the adjusted CAD-score (age, sex, hypertension), at a cut-off value of <20, NPV was 90.0 (59.6–99.5) with a PPV of 10.8 (5.3–20.6).ConclusionIn this explorative analysis, a transcutaneous ultrasensitive microphone for heart sound analysis resulted in a high NPV analogous to the findings in rule-out of stable CAD in elective patients yet inferior to serial high-sensitivity cardiac troponin measurements and does not seem feasible for application in an emergency setting for rule-out of MI.Trial registration numberNCT02355457.
Sprache
Englisch
Identifikatoren
ISSN: 2053-3624, 2398-595X
eISSN: 2053-3624
DOI: 10.1136/openhrt-2022-002090
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_40bed71822dd46e98e65189cf1b5a01c

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX