Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 6114
Intensive care medicine experimental, 2020-10, Vol.8 (1), p.58-58, Article 58
2020
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Right ventricular stroke volume assessed by pulmonary artery pulse contour analysis
Ist Teil von
  • Intensive care medicine experimental, 2020-10, Vol.8 (1), p.58-58, Article 58
Ort / Verlag
Cham: Springer International Publishing
Erscheinungsjahr
2020
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background Stroke volume measurement should provide estimates of acute treatment responses. The current pulse contour method estimates left ventricle stroke volume. Heart-lung interactions change right ventricular stroke volume acutely. We investigated the accuracy, precision, and trending abilities of four calibrated stroke volume estimates based on pulmonary artery pulse contour analysis. Results Stroke volume was measured in 9 pigs with a pulmonary artery ultrasound flow probe at 5 and 10 cmH 2 O of PEEP and three volume states (baseline, bleeding, and retransfusion) and compared against stroke volume estimates of four calibrated pulmonary pulse contour algorithms based on pulse pressure or pressure integration. Bland-Altman comparison with correction for multiple measurements and trend analysis were performed. Heart rate and stroke volumes were 104 ± 24 bpm and 30 ± 12 mL, respectively. The stroke volume estimates had a minimal bias: − 0.11 mL (95% CI − 0.55 to 0.33) to 0.32 mL (95% CI − 0.06 to 0.70). The limits of agreement were − 8.0 to 7.8 mL for calibrated pulse pressure to − 10.4 to 11.5 mL for time corrected pressure integration, resulting in a percentage error of 36 to 37%. The calibrated pulse pressure method performed best. Changes in stroke volume were trended very well (concordance rates 73–100%, r 2 0.26 to 0.987, for pulse pressure methods and 71–100%, r 2 0.236 to 0.977, for integration methods). Conclusions Pulmonary artery pulse contour methods reliably detect acute changes in stroke volume with good accuracy and moderate precision and accurately trend short-term changes in cardiac output over time.
Sprache
Englisch
Identifikatoren
ISSN: 2197-425X
eISSN: 2197-425X
DOI: 10.1186/s40635-020-00347-7
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_3fa7f73e408e4f4ebbb6f848a45c6985

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX