Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Validation of the Excited Component of the Positive and Negative Syndrome Scale (PANSS-EC) in a naturalistic sample of 278 patients with acute psychosis and agitation in a psychiatric emergency room
Ist Teil von
Health and quality of life outcomes, 2011-03, Vol.9 (1), p.18-18
Ort / Verlag
England: BioMed Central Ltd
Erscheinungsjahr
2011
Quelle
MEDLINE
Beschreibungen/Notizen
Despite the wide use of the Excited Component of the Positive and Negative Syndrome Scale (PANSS-EC) in a clinical setting to assess agitated patients, a validation study to evaluate its psychometric properties was missing.
Data from the observational NATURA study were used. This research describes trends in the use of treatments in patients with acute psychotic episodes and agitation seen in emergency departments. Exploratory principal component factor analysis was performed. Spearman's correlation and regression analyses (linear regression model) as well as equipercentile linking of Clinical Global Impression of Severity (CGI-S), Agitation and Calmness Evaluation Scale (ACES) and PANSS-EC items were conducted to examine the scale's diagnostic validity. Furthermore, reliability (Cronbach's alpha) and responsiveness were evaluated.
Factor analysis resulted in one factor being retained according to eigenvalue ≥1. At admission, the PANSS-EC and CGI-S were found to be linearly related, with an average increase of 3.4 points (p < 0.001) on the PANSS-EC for each additional CGI-S point. The PANSS-EC and ACES were found to be linearly and inversely related, with an average decrease of 5.5 points (p < 0.001) on the PANSS-EC for each additional point. The equipercentile method shows the poor sensitivity of the ACES scale. Cronbach's alpha was 0.86 and effect size was 1.44.
The factorial analyses confirm the unifactorial structure of the PANSS-EC subscale. The PANSS-EC showed a strong linear correlation with rating scales such as CGI-S and ACES. PANSS-EC has also shown an excellent capacity to detect real changes in agitated patients.